Table 101-1, For a listing of the possible alarm conditions – ADC Soneplex Broadband System User Manual
Page 316
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-293
© 2000, ADC Telecommunications, Inc.
TAP-101
Page 7 of 13
Table 101-1. Alarm Descriptions/Conditions
MPU ALARMS, AID = EQPT-MPU#
CONDITION
DESCRIPTION
GRP 1 MISMATCH
Invalid card type combination in group 1
GRP 2 MISMATCH
Invalid card type combination in group 2
GRP 3 MISMATCH
Invalid card type combination in group 3
GRP 4 MISMATCH
Invalid card type combination in group 4
GRP 5 MISMATCH
Invalid card type combination in group 5
GRP 6 MISMATCH
Invalid card type combination in group 6
GRP 7 MISMATCH
Invalid card type combination in group 7
POWER
Chassis power input (A or B) not connected
CGA
Carrier Group Alarm: 6 or more DS1’s in MAJOR alarm
EXTERNAL ALARMS, AID = EQPT-EXT#
CONDITION
DESCRIPTION
HSKP1*
Contact closure detected at HSKP IN, pair 1 on backplane
HSKP2*
Contact closure detected at HSKP IN, pair 2 on backplane
HSKP3*
Contact closure detected at HSKP IN, pair 3 on backplane
HSKP4*
Contact closure detected at HSKP IN, pair 4 on backplane
HSKP5*
Contact closure detected at HSKP IN, pair 5 on backplane
HSKP6*
Contact closure detected at HSKP IN, pair 6 on backplane
HSKP7*
Contact closure detected at HSKP IN, pair 7 on backplane
HSKP8*
Contact closure detected at HSKP IN, pair 8 on backplane
DS3 MUX ALARMS, AID = T3
CONDITION
DESCRIPTION
AIS
AIS (Alarm Indication Signal) detected
APS LIMIT
APS limit of 3 switches in 24 hours has been reached, APS disabled
FORCE TO WORK
Working module forced online, APS disabled
FORCE TO PROT
Protect module forced online, APS disabled
IDLE
Idle code detected
LOF
Loss of Frame
LOOPED BACK
Signal looped back toward network
LOS
Loss of Signal
YELLOW
Yellow alarm detected
* HSKP alarm names can be configured in the Shelf Housekeeping Labels screen, described in DLP-550.
(continued)