DLP-531
Page 3 of 7
Table 531-1. HLXC Configuration Fields
FIELD
TYPE
OPTIONS
DESCRIPTION
DEFAULT
Group
Toggle
1, 2, 3, 4, 5, 6, or 7
Specifies the module’s group number designated
on the chassis.
1
Slot
Toggle
1, 2, 3, or 4
Specifies the module’s slot number within the
group number designated on the chassis.
1
Circuit Identifier
Input
Enter up to 20
characters.
This represents the customer’s circuit ID. The first
character must be alpha or numeric; middle
characters can be alpha, numeric, or hyphens; and
the last character must be either alpha or numeric.
Note: This field can be configured only after the
T1 Provision field (described below) is set to YES.
Blank
Unit Equip State
Toggle
Equipped
Establishes communication with MPU. Module
must be set to EQUIPPED before remaining
selections are allowed.
UNEQUIPPED
UNEQUIPPED
No communication with MPU.
Unit Service State
Toggle
Leave this field at OOS at this time to avoid undesirable reporting of alarms. Set this field to
IS after completing the configuration of the remaining fields.
T1 Provision
Toggle
YES
Brings up T1 default settings and allows
configuration changes.
NO
NO
No configuration changes allowed.
T1 Service State
Toggle
Leave this field at OOS at this time to avoid undesirable reporting of alarms. Set this field to
IS after completing the configuration of the remaining fields.
T1 Framing Format
Toggle
AUTO
The system automatically detects and establishes
the current frame format (UNFRAMED, FT
ONLY, SF, or ESF). It then displays “AUTO-" and
the frame format.
AUTO
UNFRAMED
Unframed data pattern.
Ft ONLY
Used for SLC framing.
SF
Super Frame
ESF
Extended Super Frame
T1 BER Threshold
Toggle
From 10-3 to 10-9
The average Bit Error Ratios of the incoming DS1
signals are monitored by the HLXC. By
monitoring BERs, the HLXC is capable of
triggering an alarm when any of the monitored
signals degrades below the BER threshold level.
10-7
HLXC T1 Line Code
Fixed
Locked at NOT APPL.
HLXC DSX-1 EQ*
Fixed
Locked at NOT APPL.
*Note: HLXC and HLXR Switch Settings (HLXC DSX-1 EQ, HLXR LBO, Loop Power, Loop 2 Operation, and HLXR Simplex
Power) of the module being configured are displayed at the bottom of the screen.