System specifications), Table 101-2, Ds3 mux – ADC Soneplex Broadband System User Manual
Page 278: Power), Table 101-3, Table 101-4, C1 hlxc power), Tad-101
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-255
© 2000, ADC Telecommunications, Inc.
TAD-101
Page 7 of 9
Table 101-2. DS3 MUX Power Characteristics
MAX. POWER
CONSUMPTION/DISSIPATION
MAX. CURRENT DRAIN
(AT –48 VDC)
8 watts
166 mA
Note: Two DS3 MUXs (one working and one protect) are
used per chassis in Broadband (V5) applications.
Table 101-3. Broadband (V5) Power Characteristics with DLX
NO. OF DLXS IN
CHASSIS
MAX. POWER
CONSUMPTION/DISSIPATION
MAX. CURRENT DRAIN
(AT –48 VDC)
1
2 watts
41 mA
28
84 watts
1.8 amps
Note: Power characteristics for fully configured chassis include common
equipment: APU (7.5 watts), MPU (5 watts), and two DS3 MUX
modules (8 watts each), for a total of 28 watts.
Table 101-4. Broadband Power Characteristics with C1 HLXC
HLXR
CONFIGURATION
NO. OF C1 HLXCS
IN CHASSIS
MAX. POWER
CONSUMPTION
MAX. POWER
DISSIPATION
MAX. CURRENT DRAIN
(AT –48 VDC)
Span Powered B1
HLXR with DS1
Simplex Disabled
1
22.7 watts
11.9 watts
473 mA
28
664 watts
361 watts
13.8 amps
Span Powered B1
HLXR with DS1
Simplex Enabled
1
28.2 watts
12.4 watts
587 mA
28
818 watts
375 watts
17 amps
Local Powered B1
HLXR
1
8.9 watts
8.9 watts
248 mA
28
277 watts
277 watts
5.8 amps
Note: Power characteristics for fully configured chassis include common equipment: APU (7.5 watts), MPU