ADC Soneplex Broadband System User Manual
Page 236
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-213
© 2000, ADC Telecommunications, Inc.
DLP-570
Page 3 of 18
4. Use the arrow or number keys to select Test Access Unit Commands. Press Enter or Return.
The RTAU Configuration screen appears, as shown in
Figure 570-3
.
14868-A
RTAU CONFIGURATION
1. RTAU Unit Configuration
2. User Pattern Definition
Press CONTROL-A For Assistance
Figure 570-3. RTAU Configuration Menu
Note:
The User Pattern Definition screen is not available for the MPU 5.3 release.
5. Use the arrow or number keys to select RTAU Unit Configuration from the RTAU
Configuration menu. Press Enter or Return. The 'RTAU Config' screen appears, as shown
in
Note:
If the neither the RTAU or TAU are plugged into the chassis, the Test Access
Unit Status/Commands screen, shown in
, can still be accessed from the
System Maintenance menu. But in this case it cannot be configured.
However, if the TAU is plugged into the chassis, the Test Access Unit Status/Commands
screen can be configured after accessing it from the System Maintenance menu. Refer to
the Soneplex Test Access Unit Installation Instructions, listed under Related Publications
at the beginning of this manual, for more information about the TAU.
6. To prepare the RTAU for operation, set the parameters shown on the 'RTAU Config'
for test diagrams and mode schematics.
Refer to
for details regarding parameter options. Use the arrow keys to move
from field to field. Assign the selections by pressing Enter or Return.