beautypg.com

Figure 534-1, Table 534-1, Dlp-534 – ADC Soneplex Broadband System User Manual

Page 138

background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-115

© 2000, ADC Telecommunications, Inc.

DLP-534

Page 2 of 6

6127-C

RLX CONFIGURATION

Group: 1 Slot: 1 Circuit ID:

Unit Equip State : EQUIPPED Pulse Equalization : NOT APPL
Unit Service State: OOS LBO Setting : UNIT SWITCH
T1 Provision : YES Programmable Loopback : DISABLED
T1 Service State : OOS NID Loopback : UNIT SWITCH
Line Code : AUTO Loopback Activation Code : 1101001111010011
Framing Format : AUTO Loopback Deactivate Code : 1001001110010011
Network DS1 Source: NRZ Lpbk Timeout Disable Code: 1101010111010110
BER Threshold : 1E-7 Loopback Timeout Period : 0 minutes
Span Power Setting: UNIT SWITCH Network Keep Alive : AIS

DS0 Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
(B = blocked) . . . . . . . . . . . . . . . . . . . . . . . .

Unit Switch Settings: Pulse Equalization: NOT APPL Span Power: DISABLED
NID: DISABLED LBO: 7.5 dB

Press CONTROL-A For Assistance

Figure 534-1. RLX Configuration Screen

Table 534-1. RLX Configuration Fields

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

Group

Toggle

1, 2, 3, 4, 5, 6, or 7
(groups 6 and 7 are not
available in the 19-
inch chassis)

Specifies the module’s group number
designated on the chassis.

1

Slot

Toggle

1, 2, 3, or 4

Specifies the module’s slot number
designated on the chassis.

1

Circuit Identifier

Input

Enter up to 20
characters

This represents the customer’s circuit ID.
The first and last characters must be alpha
or numeric; middle characters can be alpha,
numeric, or hyphens.

Blank

Unit Equip State

Toggle

Equipped

Establishes communication with MPU.
Module must be set to EQUIPPED before
remaining selections are allowed.

UNEQUIPPED

Unequipped

No communication with MPU.

(continued)