Tad-104 – ADC Soneplex Broadband System User Manual
Page 297
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-274
© 2000, ADC Telecommunications, Inc.
TAD-104
Page 9 of 11
Table 104-4. Compressed TBOS Scan Display Definitions
DISPLAY
UNIT TYPE
DESCRIPTION
Critical Alarm
Shelf
Critical Alarm shelf summary
Major Alarm
Shelf
Major Alarm shelf summary
Minor Alarm
Shelf
Minor Alarm shelf summary
Remote Alarm
Shelf
Remote Alarm shelf summary
Power Alarm
Shelf
Shelf Power A or B input failure (but not both)
HSW Eqpt Alm
N/A
Not Applicable for this release
HSP Eqpt Alm
N/A
N/A for this release
HWS Fac Alm
N/A
N/A for this release
HSP Fac Alm
N/A
N/A for this release
MXW Eqpt Alm
MXP Eqpt Alm
DS3 MUX
Unit Fail, MPU COMM Fail, DS3 TX LOS, or (SISTER COMM Fail and not SISTER
MPU COMM Fail)
MXW Fac Alm
MXP Fac Alm
DS3 MUX
DS3 RX LOS, DS3 RX OOF, DS3 Loopback
Dxa L/R Alarm
ODS2 & QLX
DS2 Optical COMM Fail, DS2 Optical LOS, DS2 Optical OOF, DS2 Optical BER,
DS1 RX LOS, DS1 Loopback
Dx L/R Alarm
HLX
DS1 RX LOS, HDSL LOSW, HDSL BER, HDSL SNR, DC Loop Continuity (if HLXR
is line powered), DS1 Loopback
Dx L/R Alarm
RLX
DS1 RX LOS, DS1 RX LOF, DS1 Loopback
Dx L/R Alarm
DLX
DS1 RX LOS, DS1 BER, DS1 Loopback
HSKPx Rmt Alm
ODS2 & QLX
Slot number is x-1: HSKP1 alarm reporting by QFLC or QLX working.
Slot number is x-2: HSKP2 alarm reporting by QLX working only.
Slot number is x-3: HSKP3 alarm reporting by QFLC or QLX working.
Slot number is x-4: HSKP4 alarm reporting by QLX working only.
HSKPx Rmt Alm
HLX
Remote Housekeeping Alarm A or B reported by an HLXR
HSKPx Rmt Alm
RLX
N/A
HSKPx Rmt Alm
DLX
N/A
Lx Lcl Alarm
ODS2 & QLX
Unit Fail, MPU COMM Fail, Laser Degrade, DS1 TX LOS, or (SISTER COMM Fail
and not SISTER MPU COMM Fail)
Lx Lcl Alarm
HLX
Unit Fail, MPU COMM Fail
Lx Lcl Alarm
RLX
Unit Fail, MPU COMM Fail
Lx Lcl Alarm
DLX
MPU COMM Fail
Lx Rmt Alarm
ODS2 & QLX
Remote Unit Fail
Lx Rmt Alarm
HLX
N/A
Lx Rmt Alarm
RLX
N/A
Lx Rmt Alarm
DLX
N/A
a “x” represents the Soneplex chassis (shelf) slot number