beautypg.com

Tad-104 – ADC Soneplex Broadband System User Manual

Page 297

background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-274
© 2000, ADC Telecommunications, Inc.

TAD-104

Page 9 of 11

Table 104-4. Compressed TBOS Scan Display Definitions

DISPLAY

UNIT TYPE

DESCRIPTION

Critical Alarm

Shelf

Critical Alarm shelf summary

Major Alarm

Shelf

Major Alarm shelf summary

Minor Alarm

Shelf

Minor Alarm shelf summary

Remote Alarm

Shelf

Remote Alarm shelf summary

Power Alarm

Shelf

Shelf Power A or B input failure (but not both)

HSW Eqpt Alm

N/A

Not Applicable for this release

HSP Eqpt Alm

N/A

N/A for this release

HWS Fac Alm

N/A

N/A for this release

HSP Fac Alm

N/A

N/A for this release

MXW Eqpt Alm
MXP Eqpt Alm

DS3 MUX

Unit Fail, MPU COMM Fail, DS3 TX LOS, or (SISTER COMM Fail and not SISTER
MPU COMM Fail)

MXW Fac Alm
MXP Fac Alm

DS3 MUX

DS3 RX LOS, DS3 RX OOF, DS3 Loopback

Dxa L/R Alarm

ODS2 & QLX

DS2 Optical COMM Fail, DS2 Optical LOS, DS2 Optical OOF, DS2 Optical BER,
DS1 RX LOS, DS1 Loopback

Dx L/R Alarm

HLX

DS1 RX LOS, HDSL LOSW, HDSL BER, HDSL SNR, DC Loop Continuity (if HLXR
is line powered), DS1 Loopback

Dx L/R Alarm

RLX

DS1 RX LOS, DS1 RX LOF, DS1 Loopback

Dx L/R Alarm

DLX

DS1 RX LOS, DS1 BER, DS1 Loopback

HSKPx Rmt Alm

ODS2 & QLX

Slot number is x-1: HSKP1 alarm reporting by QFLC or QLX working.

Slot number is x-2: HSKP2 alarm reporting by QLX working only.

Slot number is x-3: HSKP3 alarm reporting by QFLC or QLX working.

Slot number is x-4: HSKP4 alarm reporting by QLX working only.

HSKPx Rmt Alm

HLX

Remote Housekeeping Alarm A or B reported by an HLXR

HSKPx Rmt Alm

RLX

N/A

HSKPx Rmt Alm

DLX

N/A

Lx Lcl Alarm

ODS2 & QLX

Unit Fail, MPU COMM Fail, Laser Degrade, DS1 TX LOS, or (SISTER COMM Fail
and not SISTER MPU COMM Fail)

Lx Lcl Alarm

HLX

Unit Fail, MPU COMM Fail

Lx Lcl Alarm

RLX

Unit Fail, MPU COMM Fail

Lx Lcl Alarm

DLX

MPU COMM Fail

Lx Rmt Alarm

ODS2 & QLX

Remote Unit Fail

Lx Rmt Alarm

HLX

N/A

Lx Rmt Alarm

RLX

N/A

Lx Rmt Alarm

DLX

N/A

a “x” represents the Soneplex chassis (shelf) slot number