beautypg.com

N in, Figure 525-5, Dlp-525 – ADC Soneplex Broadband System User Manual

Page 109: Page 6 of 6, Figure 525-5. rlx initial start-up test

background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-86
© 2000, ADC Telecommunications, Inc.

DLP-525

Page 6 of 6

7392-B

LPBK

STAT

V -

I-

I+

V+

LOS
BER

R
L
X

LOS
BER

NET

LINE

+

LPBK

STAT

V -

I-

I+

V+

LOSW
BER

R
L
X

ENBL

LOS
BER

NET

RESET

LINE

A2 RLX

Version B RLX

INITIAL START-UP TEST AND

STAND ALONE OPERATION

Following insertion into the mounting shelf, the STATUS
LED will initially turn red to indicate the start of self-test
diagnostics. While self-test diagnostics are in progress, all
LEDs will turn yellow and then remain on until self-test
diagnostics are completed.

Following the successful completion of self-test diagnostics,
the front panel LEDs will appear as follows:

STATUS - Green to indicate that self-test diagnostics were
successfully completed.

LPBK - Off

NET/LOS - Red to indicate that the network DS1 signal is
not being received by the RLX.

LINE/LOS - Red to indicate that the line DS1 signal is not
being received by the RLX.

Figure 525-5. RLX Initial Start-Up Test