ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-112
© 2000, ADC Telecommunications, Inc.

DLP-533

Page 4 of 5

Table 533-1. RLXIOR Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT*

Span Power
Setting**

Toggle

UNIT SWITCH

Stops span power on the RLXIOR.

ENABLED

ENABLED

Enables span power using the on-board
switch settings (–130V or ±130V). The
default switch setting is –130V.

DISABLED

Stops span power on the RLXIOR.

Pulse
Equalization**

Toggle

UNIT SWITCH

Selecting this option on the RLXIOR

creates a setting of 0–133 ft.

UNIT SWITCH (Loop
Extender chassis only)

0–133 ft., 133–266 ft.,
266–399 ft., 399–533 ft.,
or 533–655 ft.

The DS1 signal output provides standard
DSX signal levels which can be
compensated for various distances.

NOT APPL (locked field
in Broadband chassis
only)

LBO Setting**

Toggle

UNIT SWITCH

Selecting this option on the RLXIOR
creates a setting of 0.0 dB.

UNIT SWITCH

0.0 dB, 7.5 dB, 15.0 dB,
or 22.5 dB

Sets the LBO in decibels.

Programmable
Loopback

Toggle

ENABLED

Enables response to programmable
loopback codes.

DISABLED

DISABLED

Disables response to programmable
loopback codes.

NID Loopback**

Toggle

UNIT SWITCH

Disables loop-up response to NID arming
code. The loopback armed state transitions
to "Armed" when the NID arming code is
received.

ENABLED

ENABLED

Enables response to NID loopback codes.

DISABLED

Disables loop-up response to NID arming
code. The loopback armed state transitions
to "Armed" when the NID arming code is
received.

*Note: The RLXIOR configuration field default values shown in this manual are valid for systems with an MPU installed.

**Note: Although unit switch settings (Pulse Equalization, Span Power, NID Loopback, and LBO) are shown at the bottom of the
configuration screen, none of the displays are meaningful for the RLXIOR. First, there are no on-board switches for Pulse
Equalization, NID Loopback, and LBO. In addition, although the RLXIOR has an on-board Line Power switch, the Span Power
unit switch setting display is locked at “DISABLED”.

(continued)