ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-259

© 2000, ADC Telecommunications, Inc.

TAD-102

Page 2 of 5

The inband control code sequences will be recognized either in DS1 framed format (SF or ESF
framing) or in unframed format.

Table 102-1

contains a summary of loopback time-out and control codes. Notice that in the

Default Code column, the inband codes are shown left bit transmitted first and the ESF data link
codes are shown with the right bit transmitted first.

Table 102-1. HDSL Loopback Time-Out and Control Default Codes

NAME

DEFAULT CODE

DETECTION TIME

COMMENTS

Arming (inband)

Arming (ESF)

11000

0001 0010 1111 1111

> 5 seconds

4 repetitions

The signal is sent inband or over
ESF data link. HDSL units in
disarmed state make the transition
to armed state. When the inband
arming code is detected, the
smartjack loopup state activates.

Activation (HLXC)

Activation (HRX)

Activation (HLXR)

1101 0011 1101 0011

1100 0111 0100 0001

1100 0111 0100 0010

> 3 seconds

> 3 seconds

> 3 seconds

The signal is sent inband. HDSL
units go to loopup state when they
are in armed state. Loopup is
activated for selected units.

Deactivation (all
HDSL units)

1001 0011 1001 0011

> 5 seconds

The signal is sent inband. Units in

loopup state go back to armed state.

Loopup time-out
disable

1101 0101 1101 0110

> 3 seconds

Disable loopup time-out. Active

loopbacks stay up until deactivation
or disarm code is received.

Disarming (inband)

Disarming (ESF)

11100

0010 0100 1111 1111

> 5 seconds

4 repetitions

The signal is sent inband or over
ESF data link. HDSL units are
disarmed.

Arming time-out

n/a

2 hours

An armed HDSL unit goes to
disarmed state.

Loopup time-out

n/a

Programmable
from Version D
HLXC

An HDSL unit in loopup goes to
armed state.

Note: All codes are programmable.