ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-98
© 2000, ADC Telecommunications, Inc.

DLP-530

Page 3 of 3

Table 530-1. ODS2 Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

T2 Service State

Toggle

Leave this field at OOS at this time to avoid undesirable reporting of alarms.
Select IS after completing the remaining configurations.

OOS

BER Alarm
Threshold

Toggle

Set to OFF or set between
10–6 and 10–10

The average Bit Error Ratios of both the
incoming optical signals are monitored by the
ODS2. By monitoring BERs, the ODS2 is
capable of triggering a minor alarm when any of
the monitored signals degrades below the BER
threshold level.

10–8

BER Switch
Threshold

Toggle

Set between 10–4 and 10–
10

This sets the threshold at which the APS will be
executed.

10–6

Provision

Toggle

YES

Brings up T1 default settings and allows
configuration changes.

NO

(set for each T1)

NO

Facility not provisioned.

T1 Service State

Toggle

Leave this field at OOS at this time to avoid undesirable reporting of alarms.
Select IS after completing the remaining configurations.

OOS

Line Code

Toggle

AMI

Alternate Mark Inversion

AMI

(set for each T1)

B8ZS

Bipolar Eight-Zero Substitution

Circuit Identifier

Input

Enter up to 20 characters
or leave blank.

Use alphanumeric characters; embedded
hyphens are allowed.

None

(set for each T1)

Remote Pulse
Equalization

Toggle

0–133 ft., 133–226 ft.,
226–399 ft., 399–533 ft.,
533–655 ft., or NOT
APPL.

The DS1 signal output provides standard DSX
signal levels which can be compensated for at
various distances (i.e., cable length).

0–133 ft.

Remote Frame
Format

Fixed

Locked at NOT APPL.

NOT APPL

Remote PPS (Path
Protection Switch)
Threshold

Fixed

Locked at NOT APPL.

NOT APPL

T2 Service State

Toggle

IS (In-Service)

Places facility in service and allows T2 alarm
reporting by the MPU.

OOS

OOS (Out-Of-Service)

Removes facility from service and stops T2

alarm reporting by the MPU.

T1 Service State (set
for each T1)

Toggle

IS (In-Service)

Places facility in service and allows T1 alarm
reporting by the MPU.

OOS

OOS (Out-Of-Service)

Removes facility from service and stops T1

alarm reporting by the MPU.