Figure 562-1 – ADC Soneplex Broadband System User Manual
Page 220
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-197
© 2000, ADC Telecommunications, Inc.
DLP-562
Page 2 of 3
8. Move to the HDSL Facility Alarms toggle fields. Select CRITICAL, MAJOR, MINOR,
EVENT, or NOT RPTD for each field that you wish to change.
Reference
9. Assign the selections by pressing Enter or Return.
Stop! You have completed this procedure.
6153-C
HLX ALARM LEVELS
Group: 6 Slot: 1
Equipment Alarms
=============================================================================
COMM FAIL : MAJOR HSKP1 : MINOR PRIMARY POWER : MAJOR
LOOP REVERSAL : EVENT HSKP2 : MINOR SECONDARY POWER : MAJOR
TP/RNG REVERSAL : EVENT VERSION MISMATCH: MAJOR
DS1 Facility Alarms
=============================================================================
AIS : EVENT LOF : MAJOR T-BERL : MINOR
CUSTOMER LOOPBACK: MINOR LOS : MAJOR YELLOW : EVENT
NETWORK LOOPBACK : MINOR
HDSL Facility Alarms
=============================================================================
DC CONTINUITY : MAJOR T-BERP FE: MINOR T-SNR FE : EVENT
LOF FE : MAJOR T-BERP NE: MINOR T-SNR NE : EVENT
LOF NE : MAJOR T-PA FE : EVENT
RECOVERY : MINOR T-PA NE : EVENT
Press CONTROL-A For Assistance
Figure 562-1. HLX Alarm Levels Screen (with Default Values)