Figure 542-1, Of the alarm, Figure 542-2 – ADC Soneplex Broadband System User Manual

Page 170: T1 hlxc/hrx/hlxr nend, Dlp-542, Page 2 of 4, Figure 542-1. active alarms screen (sample)

background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-147

© 2000, ADC Telecommunications, Inc.

DLP-542

Page 2 of 4

6675-A

ACTIVE ALARMS
Legend:

Access ID=Identifier[-]Shelf-Grp-Slot[-Site(1=Lcl,2=Rmt) | -Loop(1=Lp 1,2=Lp 2)]

Access ID Locn Circuit ID Condition Status ACO
---------------- ---- -------------------- ---------------- ------ ---
T2-1-3-1 NEND OPTICAL LOS MJ NO
T2-1-3-1 NEND OPTICAL LOF MJ NO
HDSL-1-7-1-1 NEND RECOVERY MN NO
HDSL-1-7-1-1 NEND LOF MJ NO
HDSL-1-7-1-1 NEND T-BERP MN NO
HDSL-1-7-1-1 NEND T-SNR EV NO
HDSL-1-7-1-1 FEND LOF MJ NO
HDSL-1-7-1-1 FEND T-BERP MN NO
HDSL-1-7-1-1 FEND T-SNR EV NO
HDSL-1-7-1-2 NEND RECOVERY MN NO
HDSL-1-7-1-2 NEND LOF MJ NO
HDSL-1-7-1-2 NEND T-BERP MN NO
HDSL-1-7-1-2 NEND T-SNR EV NO
HDSL-1-7-1-2 FEND LOF MJ NO
HDSL-1-7-1-2 FEND T-BERP MN NO
HDSL-1-7-1-2 FEND T-SNR EV NO

Page 1 of 1 Press CONTROL-A for assistance

Figure 542-1. Active Alarms Screen (Sample)

KEY

NEND means "PM information collected directly from incoming T1 signals, both at local and remote sites."

FEND means "ESF PRM information collected at the opposite ends of spans from the affected circuit and

returned to the system via the ESF Datalink, both at local and remote sites". The framing format must be

ESF in order for FEND information to be displayed.

Note: For Site 1, FEND information is at A; for Site 2, FEND information is at B.

10263-A

NEND

NEND

FEND

HRX

HLXC

HLXR

FEND

REMOTE

(SITE = -2)

LOCAL

(SITE = -1)

LOOP 1

LOOP 2

LOOP 1

LOOP 2

DS1

DS1

DS1

DS1

TO NETWORK

TO CUSTOMER

A

B

Figure 542-2. T1 HLXC/HRX/HLXR NEND and FEND Locations