Fer to, Table 529-1, Refer to – ADC Soneplex Broadband System User Manual
Page 116: Figure 529-1, For a detailed drawing of the switch. when a c1, The remote control chassis, Figure 529-2, Shows the location of the switch on the ds3 mux, Dlp-529
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-93
© 2000, ADC Telecommunications, Inc.
DLP-529
Page 2 of 4
4. Starting at the top of
and working your way to the bottom, configure the DS3
MUX fields.
5. Assign the selections by pressing Enter or Return.
Stop! You have completed this procedure.
Table 529-1. C1 and D1 DS3 MUX and DS3 CAM
DIP Switch Settings for DS3 Soneplex Remote Control System
C1 AND D1 DS3 MUX SWITCH
DS3 CAM SWITCH
CHANNEL
1
2
3
1
2
3
7
N/A
OPEN
OPEN
OPEN
OPEN
N/A
6
N/A
OPEN
CLOSED
OPEN
CLOSED
N/A
5
N/A
CLOSED
OPEN
CLOSED
OPEN
N/A
2
N/A
CLOSED
CLOSED
CLOSED
CLOSED
N/A
Note: The default setting is channel 7 for both the C1 and D1 DS3 MUX and the DS3 CAM.
Note: The CLOSED/OPEN position indicates that the switch is depressed in that direction.
10509-A
OPEN
1
2
3
CLOSED
(ON)
OPEN
(OFF)
ON OFF
All switches shown are in the OFF position.
1
2
3
OPEN
STATUS
DS3 M
UX
RESET
LPBK
APS
ENABLE
ONLINE
LMPTST/
APS
DS3 FAIL
LOCKOUT
FORCE
7902-A
Figure 529-1. C1 and D1 DS3
Figure 529-2. C1 and D1 DS3 MUX Channel
MUX DIP Switch Detail
Selection DIP Switch Location