4. Starting at the top of

Table 529-2

and working your way to the bottom, configure the DS3

MUX fields.

5. Assign the selections by pressing Enter or Return.

Stop! You have completed this procedure.

Table 529-1. C1 and D1 DS3 MUX and DS3 CAM

DIP Switch Settings for DS3 Soneplex Remote Control System

C1 AND D1 DS3 MUX SWITCH

DS3 CAM SWITCH

CHANNEL

1

2

3

1

2

3

7

N/A

OPEN

OPEN

OPEN

OPEN

N/A

6

N/A

OPEN

CLOSED

OPEN

CLOSED

N/A

5

N/A

CLOSED

OPEN

CLOSED

OPEN

N/A

2

N/A

CLOSED

CLOSED

CLOSED

CLOSED

N/A

Note: The default setting is channel 7 for both the C1 and D1 DS3 MUX and the DS3 CAM.
Note: The CLOSED/OPEN position indicates that the switch is depressed in that direction.

10509-A

OPEN

1

2

3

CLOSED

(ON)

OPEN

(OFF)

ON OFF

All switches shown are in the OFF position.

1

2

3

OPEN

STATUS

DS3 M

UX

RESET

LPBK

APS

ENABLE

ONLINE

LMPTST/
APS

DS3 FAIL

LOCKOUT
FORCE

7902-A

Figure 529-1. C1 and D1 DS3

Figure 529-2. C1 and D1 DS3 MUX Channel

MUX DIP Switch Detail

Selection DIP Switch Location