Table 104-3. Expanded Scan Displays 2 Through 8 Definitions

DISPLAY

MODULE TYPE

DESCRIPTION

Lx

1

EQPT Fail

QLX

Module Fail, MPU COMM Fail, Laser Degrade, DS1 TX
LOS or (SISTER COMM Fail and not SISTER MPU
COMM Fail).

HLXC/RLX

BOARD Fail or MPU COMM Fail

Lx

1

EQPT Fail RMT

QLX

Remote Board Fail

HLXC/RLX

Not Applicable

Lx

1

Link ALM

QLX

DS2 OPTICAL COMM Fail, DS2 OPTICAL LOS, DS2
OPTICAL OOF, or DS2 OPTICAL BER

HLXC

LOS, BER or SNR

RLX

BER

Lx

1

RMT Link ALM

QLX

REMOTE OPTICAL COMM Fail, REMOTE DS2
OPTICAL LOS, REMOTE DS2 OPTICAL OOF, or
REMOTE OPTICAL DS2 BER

HLXC

REMOTE LOSW, DC Loop Continuity (if HLXR is line
powered), BER, or SNR

RLX

Not Applicable

Dx

1

SIG Fail

QLX,/HLXC

DS1 RX LOS

Dx

1

RMT SIG Fail

QLX,/HLXC

Remote DS1 RX LOS

Lx

1

RMT HSKP A/B

QLX

Remote Housekeeping Alarm A reported by QFLC. Remote

Housekeeping Alarm B is not applicable.

HLXC

Remote Housekeeping Alarm A or B reported by an HLXR.

RLX

Not Applicable

Lx

1

APS DIS

QLX

Lx

1

APS Status or Lx

1

APS lockout status

1

- x represents the chassis slot number.