ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-251

© 2000, ADC Telecommunications, Inc.

TAD-101

Page 3 of 9

Table 101-1. Soneplex Broadband System (V5) Specifications, continued

PARAMETER

SPECIFICATION

REMARKS

Version D and later HLXC
Modules

Loop Loss

< 35 dB @ 196 kHz

135 ohm termination

Loop Types

Two-pair, single or mixed gauges With or without bridged taps

Transmission:

Format

Two 784 kbps full duplex pairs,
2B1Q modulation

Line Impedance

135 ohms nominal

Balanced

Loop Power Output Voltage

–132 ± 5 VDC (without HRX)
±130 VDC (with HRX)

Return Loss

>20 dB

40 kHz to 200 kHz

Total Signal Power

+13.5 dBm ± 0.5 dBm

B1 HLXR

DS1 Interface:

Input / Output Signals

Per ANSI T1-403

Frequency

1.544 Mbps

HDSL Interface:

Format

Two 784 kbps full duplex pairs,
2B1Q

Impedance

135 ohms

Loop Loss

<35 dB

196 kHz

Loop Type

Two pair, single or mixed gauges

With or without bridged taps

Output Signal Level

+13.5 dBm

Return Loss

>20 dB

40 to 200 kHz

Power

–42 to –56 VDC (local)

85 to

130 VDC (line)

(continued)