Show log, Syntax, Parameters – Allied Telesis AT-S63 User Manual
Page 201
AT-S63 Management Software Command Line Interface User’s Guide
201
SHOW LOG
Syntax
show log=permanent|temporary [full] [module=
module
]
[reverse] [severity=
severity
]
Parameters
log
Specifies which of the two event logs you want to
view. The options are:
permanent
Displays the events stored in
permanent memory.
temporary
Displays the events stored in
temporary memory.
full
Specifies the amount of information displayed by the
log. Without this option, the log displays the time,
module, severity, and description for each entry. With
it, the log also displays the filename, line number, and
event ID.
module
Specifies the AT-S63 module whose events you want
displayed. For a list of modules, refer to Table 4 on
page 202.
reverse
Specifies the order of the events in the log. Without
this option, the events are displayed oldest to newest.
With this option, the events are displayed newest to
oldest.
severity
Specifies the severity of events to be displayed. The
options are:
all
Displays events of all severity levels. This
is the default
severity
Displays events of a particular severity.
Choices are I for Informational, E for Error,
W for Warning, and D for Debug. You can
select more than one severity at a time (for
example, E,W). For a definition of the
severity levels, see Table 5, “Event Log
Severity Levels” on page 204.