Description, Examples – Allied Telesis AT-S63 User Manual
Page 115
AT-S63 Management Software Command Line Interface User’s Guide
115
frames. These options
are equivalent.
no, off, false, disabled The port discards all
unknown multicast
frames. These options
are equivalent.
unkucastfiltering
Controls the unknown unicast filter. The options
are:
yes, on, true, enabled The port forwards
unknown unicast
frames. These options
are equivalent.
no, off, false, disabled The port discards all
unknown unicast
frames. These options
are equivalent.
Description
This command sets a port’s operating parameters. You can set more than
one parameter at a time. For an explanation of the port parameters, refer
to Chapter 6, “Port Parameters” in the AT-S63 Management Software
Menus Interface User’s Guide.
Examples
The following command disables ports 1 to 6:
set switch port=1-6 status=disabled
The following command configures port 8 to operate at 10 Mbps, half
duplex:
set switch port=8 speed=10mhalf
The following command sets the speed to 100 Mbps, the duplex mode to
full duplex, the wiring configuration to MDI-X, and flow control to enabled
for ports 2 to 6:
set switch port=2-6 speed=100mfull mdimode=mdix
flowcontrol=enabled
The following command sets port priority to 5 and activates the broadcast
filter for ports 5, 8, and 12:
set switch port=5,8,12 priority=5 bcastfiltering=enabled
The following command resets port 5: