A.6.8 integrated processing, A.6.9 spatial processing – Campbell Scientific CR3000 Micrologger User Manual
Page 502

Appendix A. CRBasic Programming Instructions
502
A.6.8 Integrated Processing
DewPoint 
Calculates dew point temperature from dry bulb and relative humidity. 
Syntax
DewPoint(Dest, Temp, RH)
PRT 
Calculates temperature from the resistance of an RTD.  This instruction has been 
superseded by PRTCalc() in most applications. 
Syntax
PRT(Dest, Reps, Source, Mult)
PRTCalc 
Calculates temperature from the resistance of an RTD according to a range of 
alternative standards, including IEC. 
Syntax
PRTCalc(Dest, Reps, Source, PRTType, Mult, Offset)
SolarPosition 
Calculates solar position 
Syntax
SolarPosition(Dest, Time, UTC_OFFSET, Lat_c, Lon_c, Alt_c,
Pressure, AirTemp)
SatVP 
Calculates saturation‐vapor pressure (kPa) from temperature. 
Syntax
SatVP(Dest, Temp)
StrainCalc 
Converts the output of a bridge‐measurement instruction to microstrain. 
Syntax
StrainCalc(Dest, Reps, Source, BrZero, BrConfig, GF, v)
VaporPressure 
Calculates vapor pressure from temperature and relative humidity. 
Syntax
VaporPressure(Dest, Temp, RH)
WetDryBulb 
Calculates vapor pressure (kPa) from wet‐ and dry‐bulb temperatures and 
barometric pressure. 
Syntax
WetDryBulb(Dest, DryTemp, WetTemp, Pressure)
A.6.9 Spatial Processing
AvgSpa 
Computes the spatial average of the values in the source array. 
Syntax
AvgSpa(Dest, Swath, Source)