7.8.8.6.2 Create Send Text File
Create a file from which to send a serial string. The file shown in figure
HyperTerminal Send Text-File Example
(p. 219)
will send the string
[2008:028:10:36:22]C to the CR3000. Use Notepad (Microsoft Windows utility)
or some other text editor that will not place unexpected hidden characters in the
file.
Figure 75: HyperTerminal send text-file example
To send the file, click Transfer | Send Text File | Browse for file, then click OK.
7.8.8.6.3 Create Text-Capture File
Figure HyperTerminal Text-Capture File Example
(p. 219)
shows a HyperTerminal
capture file with some data. The file is empty before use commences.
Figure 76: HyperTerminal text-capture file example
Engage text capture by clicking on Transfer | Capture Text | Browse, select the
file, and then click OK.
7.8.8.6.4 Serial Input Test Program
CRBasic example Measure Sensors / Send RS-232 Data
(p. 220)
illustrates a use of
CR3000 serial I/O features.
Problem: An energy company has a large network of older CR510 dataloggers
into which new CR3000 dataloggers are to be incorporated. The CR510
dataloggers are programmed to output data in the legacy Campbell Scientific
Printable ASCII format, which satisfies requirements of the customer's data-
acquisition system. The network administrator also prefers to synchronize the
CR510 clocks from a central computer using the legacy Campbell Scientific C
command. The CR510 datalogger is hard-coded to output Printable ASCII and