1 file attributes, Table 83. cr3000 file attributes – Campbell Scientific CR3000 Micrologger User Manual
Page 347

Section 8. Operation
347
Table 82. File-Control Functions
File-Control Functions
Accessed Through
Create a data file from a data table
TableFile()
6
JPEG files manager
integrated keyboard / display , LoggerNet |
PakBusGraph, web API NewestFile
Hiding files
Web API FileControl
Encrypting files
Web API FileControl
Abort program on power-up
Hold DEL down on datalogger keypad
1
Datalogger support software
(p. 76)
Program Send
command
2
Datalogger support software File Control (p. 456) utility
3
Device Configuration Utility (DevConfig)
(p. 97)
software
4
Manual with CF card (CRD: drive) or Campbell Scientific mass-storage media (USB: drive). See
Data Storage
(p. 338)
5
Automatic with CF card (CRD: drive) or Campbell Scientific mass-storage media (USB: drive)
and Powerup.ini. See Power-up
(p. 348)
6
CRBasic instructions (commands). See Data-Table Declarations
(p. 477)
and File Management
and CRBasic Editor Help.
7
Datalogger support software Retrieve (p. 456) command
8.3.4.1 File Attributes
A feature of program files is the file attribute. Table CR3000 File Attributes
(p. 347)
lists available file attributes, their functions, and when attributes are typically
used. For example, a program file sent via the support software Program Send
command, runs a) immediately ("run now"), and b) when power is cycled on the
CR3000 ("run on power-up'). This functionality is invoked because Program
Send
sets two CR3000 file attributes on the program file, i.e., Run Now and Run
on Power-up. When together, Run Now and Run on Power-up are tagged as
Run Always.
Note Activation of the run-on-power-up file can be prevented by holding down
the Del key on the integrated keyboard / display while the CR3000 is powering
up.
Table 83. CR3000 File Attributes
Attribute
Function
Attribute for Programs Sent to CR3000 with:
Run Always
(run on power-up +
run now)
Runs now and on
power-up.
a) Send
(p. 456)
1
b) File Control
2
with Run Now & Run on Power-up
selected.
c) CF card (CRD: drive) or Campbell Scientific
mass-storage media (USB: drive) power-up
3
using
commands 1 & 13 (see table Powerup.ini Commands
(p. 350)
).
Run on Power-up
Runs only on
power-up
a) File Control
2
with Run on Power-up checked.
b) CF card (CRD: drive) or Campbell Scientific
mass-storage media (USB: drive) power-up
3
using
command 2 (see table Powerup.ini Commands
(p.
).