4 groundwater pump test, Crbasic example 55. groundwater pump test – Campbell Scientific CR3000 Micrologger User Manual

Page 252

background image

Section 7. Installation

252 

 

 

'Main Program

BeginProg

'Begin executable section of program

Scan

(1,Sec,0,0)

'Begin main scan

PanelTemp

(PTemp,250)

Counter1 = Counter1 + 1

NextScan

'End main scan

SlowSequence

'Begin slow sequence

'Declare Public Variables for Secondary Scan (can be declared at head of program)

Public

Batt_Volt

Public

Counter2

'Declare Data Table

DataTable

(Test,1,-1)

'Data Table “Test” is event driven.

'The event is the scan.

Minimum

(1,batt_volt,FP2,0,False)

Sample

(1,PTemp,FP2)

Sample

(1, counter, fp2)

EndTable

Scan

(5,Sec,0,0)

'Begin 1st secondary scan

Counter2 = Counter2 + 1

Battery

(Batt_volt)

CallTable

Test

'Call Data Table Test

NextScan

'End slow sequence scan

EndProg

'End executable section of program

 

7.8.17.4 Groundwater Pump Test

CRBasic example Groundwater Pump Test

(p. 252)

demonstrates:

1. How to write multiple-interval data to the same data table.

2. Use of program-control instructions outside the Scan() / NextScan structure.

3. One way to execute conditional code.

4. Use of multiple sequential scans, each with a scan count.

CRBasic Example 55. Groundwater Pump Test 

'A groundwater pump test requires that water level be measured and recorded

'according to the following schedule:

'Minutes into Test Data Interval

'----------------- -------------

' 0-10 10 seconds

' 10-30 30 seconds

' 30-100 1 minute

' 100-300 2 minute

' 300-1000 5 minute

' 1000 + 10 minute