beautypg.com

Campbell Scientific CR3000 Micrologger User Manual

Page 116

background image

Section 7. Installation

116 

 

 

Note To retain data, Preserve data if no table changed must be selected
whether or not CF card (CRD: drive) or Campbell Scientific mass-storage media
(USB: drive) be connected.

Regardless of the program-upload tool used, if any change occurs to data table
structures listed in table Data Table Structures

(p. 116),

data will be erased when a

new program is sent.

Table 8. Program Send Options that Reset

Memory*

LoggerNet | Connect | Program Send

PC400 | Clock/Program | Send Program

PC200W | Clock/Program | Send Program

RTDAQ | Clock/Program | Send Program

DevConfig | Logger Control | Send Program

*Reset memory and set program attributes to Run Always

 

Figure 48: CRBasic Editor Program Send File Control window

Table 9. Data Table

Structures

-Data table name(s)

-Data interval or offset

-Number of fields per record

-Number of bytes per field

-Field type, size, name, or position

-Number of records in table