Campbell Scientific CR3000 Micrologger User Manual
Page 395

Section 8. Operation
395
time
Specifies the current value of the CR3000 real-time clock
2
. This
value will only be valid if the value of outcome is set to 1. This
value will be formatted in the same way that record time stamps
are formatted for the DataQuery response.
description
A text string that describes the outcome.
1
LoggerNet may combine a new clock check transaction with pending LoggerNet clock set
transactions
2
or LoggerNet server
HTML Response
When
html
is entered in the ClockCheck
format
parameter, the response will be
HTML. Following are example responses.
HTML tabular response:
HTML page source:
"http://www.w3.org/TR/html4/loose.dtd">
ClockCheck Response
outcome | 1 | time | 2012-08-24 15:44:43.59 |
description | The clock was checked |
XML Response
When
xml
is entered in the ClockCheck
format
parameter, the response will be
formated as CSIXML
(p. 68)
with a ClockCheckResponse root element name.
Following is an example response.
JSON Response
When
json
is entered in the ClockCheck
format
parameter, the response will be
formated as CSIJSON
(p. 68).
Following is an example response.
Example:
{
"outcome": 1,
"time": "2012-08-24T15:52:26.22",
"description": " The clock was checked"
}