Section 7. Installation

186 

 

 

CRBasic Example 33. Using Alternate Concurrent Command (aC) 

'Code to use when back to back SDI-12 concurrent measurement commands not desired

'Main Program

BeginProg

'Preset first measurement command to C!

For

X = 1

To

4

cmd(X) = "C!"

Next

X

'Set 5 s scan rate

Scan

(5,Sec,0,0)

'Other measurements here

'Set 5 minute measurement rate

If

TimeIntoInterval

(0,5,Min)

Then

RunSDI12 = True

'Begin measurement sequence

If

RunSDI12 = True

Then

For

X = 1

To

4

Temp_Tmp(X) = 2e9

'when 2e9 changes, indicates a change

Next

X

'Measure SDI-12 sensors

SDI12Recorder

(Temp_Tmp(1),1,0,cmd(1),1.0,0)

SDI12Recorder

(Temp_Tmp(2),1,1,cmd(2),1.0,0)

SDI12Recorder

(Temp_Tmp(3),1,2,cmd(3),1.0,0)

SDI12Recorder

(Temp_Tmp(4),1,3,cmd(4),1.0,0)

'Control Measurement Event

For

X = 1

To

4

If

cmd(X) = "C!"

Then

Retry(X) = Retry(X) + 1

If

Retry(X) > 2

Then

IndDone(X) = -1

'Test to see if ttt expired. If ttt not expired, load "1e9" into first

'variable then moves to next instruction. If ttt expired, issue

'aDv! command(s).

If

((Temp_Tmp(X) = 2e9)

OR

(Temp_Tmp(X) = 1e9))

Then

cmd(X) = "C"

'Start sending "C" command.

ElseIf

(Temp_Tmp(X) = NAN) Then

'Comms failed or sensor not attached

cmd(X) = "C!"

'Start measurement over