HP Insight Control Software for Linux User Manual

Page 32

background image

2.

Select the target.

The target must be the corresponding iLO-based management processor. Ensure that the
management processor has already been discovered by HP SIM; the management processor
should not be licensed.

NOTE:

Take care that all target management processors are iLO-based:

If you select a single target management processor that is not an iLO-based management
processor, the tool will not let you proceed and will display No in the Tool launch OK?
field of the Verify Target Systems window.

If you select several target management processors, the Network Configuration Editor
accepts only the iLO-based management processors.

If you select a collection (for example, All Management Processors), the Network
Configuration Editor cannot exclude any management processors that are not iLO-based.

As a consequence:

— There will be a delay while the Network Configuration Editor attempts to collect

data from these non-iLO management processors

— These management processors will not be able to perform any virtual media

functions.

3.

Verify the target or targets, then select Run Now. The Network Configuration Editor page
appears.

Figure 2-2 Network Configuration Editor page

4.

Optionally verify the management processor by moving the mouse pointer over the
Management Processor Name

field, but do not select it. The management processor's

serial number and IP address are displayed to help you identify it.

5.

In the Server Host Name field, enter a unique name for the server associated with the
management processor.

32

Configuring network parameters for virtual media