4 changing the ip address of the cms, 5 uninstalling hp insight control for linux – HP Insight Control Software for Linux User Manual
Page 206
Wait for two to three minutes for HP SIM to restart completely.
21.3 Increasing the number of servers that can be discovered concurrently
When performing a
discovery on a set of servers, the maximum number of nodes that
will be discovered concurrently is 16.
Perform the following steps to increase that number:
1.
Edit the /opt/mx/icle/icle.properties file to add the following line:
DISCOVERY_MAX_AT_ONCE=servers
Where servers is an integer value representing the number of servers that will be discovered
concurrently.
2.
Restart HP SIM.
21.4 Changing the IP address of the CMS
1.
Run Deploy
→Deploy Drivers, Firmware and Agents→IC-Linux→Uninstall Agents on
all your
s to remove the Insight Control for Linux management agents.
2.
Stop HP SIM:
# /opt/mx/bin/mxstop
3.
Edit the following files on your CMS and replace all occurrences of the old CMS IP address
with your new CMS IP address:
/etc/hosts
/opt/hptc/etc/sysconfig/cmsserver.ini
/opt/hp/icelx/config/iceInstallerAnswers
/opt/mx/icle/icle.properties
/etc/opt/mx/config/RootTrustList.txt
/opt/hptc/perl/lib/raapisRPCervice.pm
1
)
/opt/hptc/perl/lib/sim/MxpiMainService.pm
4.
4. Start HP SIM:
# /opt/mx/bin/mxstart
5.
Run Configure
→Configure or Repair Agents on all your managed systems so that
snmpd.conf
is updated with the new CMS IP address.
6.
Run Options
→IC-Linux→Configure Management Services... to reconfigure the Insight
Control for Linux management services.
21.5 Uninstalling HP Insight Control for Linux
To uninstall HP Insight Control for Linux, follow this procedure:
1.
If you have installed the HP Insight Control for Linux management agents, select the
following menu item from the HP Insight Control user interface to remove the management
agents from all managed systems:
Deploy
→Deploy Drivers, Firmware and Agents→IC-Linux→Uninstall Agents...
2.
Run the following script to unconfigure syslog-ng on the CMS:
# /opt/hptc/etc/cconfig.d/C30syslogng_forward cunconfigure
3.
Remove the Insight Control for Linux SSH keys for pdsh, which are located in the /root/
.ssh/
directory. The file names are prefixed with the Insight Control for Linux collection
name. The following example uses the default collection name, icelx_:
# rm /root/.ssh/icelx_*
1. This file only exists on HP Insight Control for Linux V2.10 and higher.