Table 1 File Level Parameters

File Level Parameters Data Type

Default Value

Minimum

Maximum

Accuracy

Integer

1

1

4

RSSI Calibration

Integer

-10 dB

-40 dB

40 dB

Spillage Factor

Positive Integer

2

2

3

Min Attenuation Factor

Real

2

1.6

4

Max Attenuation Factor

Real

2

1.6

4

Alpha

Real

-4

Not applicable

Not applicable

Beta

Real

0.08

Not applicable

Not applicable

Table 2 Application Level Parameters

Application Level

Parameters

Data Type

Default Value

Minimum

Maximum

Coverage Estimation

Thresholds

Integer

-40, -50, -55, -60

dBm

-100 dBm

-10 dBm

Sensor Detection

Threshold

Integer

-85 dBm

-150 dBm

-20 dBm

Sensor Redundancy

Integer

1

1

10

Sensor Prevention

Thresholds

Integer

-65, -60, -55 dBm

(low

-20 dBm

Device Transmit Power

Integer

13

0

20

Channel View Threshold Integer

-85 dBm

-150 dBm

-20 dBm

AP Redundancy

Integer

1

1

10

In addition to these parameters, Planner also has the following application level parameters:

1 Region Settings in ToolsSettingsPreferencesAP Views
2 Default Access Point Settings
3 Auto Channel Select
4 ‘Do not show this window again’ messages
5 Color Palettes
6 Report Base Folder

Note: The default installation values are selected when you install a new version of Planner.