Show drive type, Show firmware available, Show drive type show firmware available – HP Command View for Tape Libraries Software User Manual
Page 225

Operands
Specify a tape drive for which to display the status. The tape
drive status may be displayed for all tape drives by specifying
all
for this operand. This operand is required.
drive_num
Examples
To show the status for all tape drives:
/>show drive status all
Tape Drive status:
Is Firmware Has
Drive Number serialNumber Status Available Mismatch Errors
------------ -------------- -------- --------- --------- --------
Drive 1 HU72M09167 Green No No No
Drive 2 HU72M09172 Yellow Yes Yes Yes*
*Use the command 'show drive status' with a specific drive number to see
specific errors for this device.
See also
show drive type
Description
Shows the tape drive type for one or more tape drives.
Syntax
show drive type [drive_num] | [all]
Availability
All users and modes
Operands
Specify a tape drive for which to display the type. The type
may be displayed for all tape drives by specifying all for
this operand. This operand is required.
drive_num
Examples
To show the tape drive type for all tape drives:
/>show drive type all
Tape drive type:
Drive Number type
---------------- ----------------
Drive 1 Ultrium 1-SCSI
Drive 2 Ultrium 1-SCSI
See also
show firmware available
Description
Shows the firmware files and revisions available to be downloaded to devices.
Syntax
show firmware available
Availability
All users and modes
Operands
None
show drive type 225