background image

The following table describes the CHIP/CHA summary table for an XP disk array and the CHA summary
table for a P9000 disk array.

CHA summary table for P9000 disk arrays in-
cludes...

CHIP/CHA summary table for XP disk arrays includes...

The CHA name
Example: CHA-1F, 1 indicates the cluster # where
the CHA board is located.

The CHIP or the CHA name
Example: CHA-1EU

Not applicable

The individual MPs and their utilization percentage

In the above image, XX in CHPXX-IEU indicates the corresponding MP ID, which
can be 00, 01, 02, or 03. The CHPXX-IEU utilization % indicates the MP
utilization percentage, which is as follows:

CHP00-1EU is 7%

CHP01-1EU is 2%

CHP02-1EU is 33%

CHP03-1EU is 2%

Not applicable

The MP to port mapping data, where the associated port IDs appear in the
respective MP utilization blocks.

In the above image, the MP- port mapping for the CHIP, CHA-1EU is as follows:

CHP00-1EU - associated ports are CL1A and CL5A

CHP01-1EU - associated ports are CL3A and CL7A

CHP02-1EU - associated ports are CL1B and CL5B

CHP03-1EU - associated ports are CL3B and CL7B

The average port activity (I/Os and MB/s) of all
the associated ports in the Port Activity Avg block.

In the above image, the average port I/Os is
7389.40 and the average port MB/s is 57.73.

The average port activity (I/Os and MB/s) of all the associated ports in the Port
Activity Avg block.

In the above image, the average port I/Os is 2739.00 and the average port
MB/s is 170.95.