Hp-ux configuration, Emulex hba configuration, Configuring san – HP 8.20q Fibre Channel Switch User Manual
Page 17: Connection manager for hp-ux and emulex hbas
HP SAN Connection Manager User Guide
17
6.
To verify that the installation completed, check the FC HBA driver version:
a. To ensure that the driver is installed in the correct location, issue the following command:
# modinfo qla2xxx
The following is returned:
Filename: /lib/modules/2.6.9-55.ELsmp/kernel/drivers/scsi/qla2xxx/qla2xxx.ko
Version: 8.02.23 653675A771C3619AEEA4E9A
b. To verify that the driver is loaded, issue the following command:
# lsmod | grep qla2xxx
The following is returned:
qla2xxx_conf
303752
1
qla2xxx
982688
0
scsi_mod
445298
qla2xxx
c. To verify that the correct driver is loaded, issue the following command:
# cat /proc/scsi/qla2xxx/* | grep "Driver version"
The following is returned:
Firmware version: 3.03.25 IPX
Driver version: 8.02.23-fo
Configuring SAN Connection Manager for HP-UX and Emulex HBAs
SAN Connection Manager is compatible with the HP-UX operating system and Emulex HBAs when
configured as described in this section.
HP-UX configuration
SAN Connection Manager can manage all of your supported HP-UX servers. The HP-UX operating system
provides native software drivers for the HP FC HBAs. For the application to properly identify your server(s),
you must manually enter the FDMI information when the application prompts for it. For more information,
“Manually entering FDMI information,”
Emulex HBA configuration
SAN Connection Manager can manage all of your supported Windows and Linux servers that have
Emulex HBAs installed. In order for the application to properly identify your server(s), you must set the
EnableFDMI
parameter on the Emulex HBA. Use the HBAnyware software to set the EnableFDMI
parameter to a value of 2.
For detailed instructions on how to enable the FDMI parameter on your Emulex HBA, see your HBA
documentation.
If FDMI is not enabled on the HBA, SAN Connection Manager will prompt you to manually enter the FDMI
information. For more information, see
“Manually entering FDMI information,”
Installing SAN Connection Manager: upgrade installation
Use the HP SAN Connection Manager CD to upgrade a previous installation of the management software
on your management station as described in
“Windows installation: upgrade,”
page 18. Then use the
same CD to upgrade the HBA driver and other required software on each of the other servers in your SAN.
Depending on the server operating system for the non-management station installations, refer to either the
steps for
“Windows installation: upgrade,”