beautypg.com

HP XP Performance Advisor Software User Manual

Page 392

background image

Table 40 Metrics and descriptions (continued)

Description

Metric

Metric category

The total IO writes is obtained
by summing up IO writes of

The total IO writes of all the
LDEVs created in a specified

Total IO Writes – Frontend

all the LDEVS for the given
host group.

RAID group for the given
Host group over the entire
data collection interval.

The total IO reads is obtained
by summing up IO reads of

The total IO reads of all the
LDEVs created in a specified

Total IO Reads – Frontend

all the LDEVS for the given
host group.

RAID group for the given
Host group over the entire
data collection interval.

The total IO Miss is obtained
by summing up IO miss of all

The total IO miss of all the
LDEVs created in a specified

Total IO Miss – Frontend

the LDEVS for the given host
group.

RAID group for the given
Host group over the entire
data collection interval.

Each RAID group value is the
sum of the LDEVs in the RAID
group.

The sum total of the frontend
I/Os on all the LDEVs
created in a RAID group.

RAID Group Total IO –
Frontend

The sum total of the frontend
random I/Os on all the

RAID Group Total Random
IO – Frontend

LDEVs created in a RAID
group.

The frontend random read
I/Os on all the LDEVs
created in a RAID group.

RAID Group Random Reads
– Frontend

Out of the sum total of
frontend random read I/Os

RAID Group Random Reads
Cache Hits – Frontend

on all the LDEVs created in
a given RAID group, the
number of random reads
available in the cache.

The frontend random write
I/Os on all the LDEVs
created in a RAID group.

RAID Group Random Writes
– Frontend

The sum total of frontend
sequential I/Os on all the

RAID Group Total Sequential
IO – Frontend

LDEVs created in a RAID
group.

The frontend sequential read
I/Os on all the LDEVs
created in a RAID group.

RAID Group Sequential
Reads – Frontend

The number of sequential
frontend read I/Os serviced

RAID Group Sequential
Reads Cache Hits – Frontend

from the cache in terms of
the I/Os writes for a RAID
group.

The frontend sequential write
I/Os on all the LDEVs
created in a RAID group.

RAID Group Sequential
Writes – Frontend

Each ThP pool value is the
sum of all the LDEVs in the
ThP.

The cumulative frontend
I/Os over the entire
collection interval on

Total IO - Frontend

individual virtual volumes
defined in this pool.

392 Metric Category, metrics, and descriptions