beautypg.com

HP XP Performance Advisor Software User Manual

Page 391

background image

Table 40 Metrics and descriptions (continued)

Description

Metric

Metric category

example, if collection
interval is set to five minutes,
the maximum port IO value
is collected and verified
against the previous value
every one minute, and the
highest port I/O value
collected in the last five
minutes is considered.

The average frontend I/Os
rate on this port over an

Average Port IO – Frontend

entire collection interval. Port
Average IO shown in PA is
average of average IO.
Average Port IO is the value
within a period of sampling
time at one minute interval
from RMLIB call (this could
be running average in a
min). PA collects this data
every minute and updates
according to the configured
port collection frequency.
For example, consider port
collection is configured for
5 minutes, then every minute
average port data is
collected and stored
in-memory. At the end of 5th
minute, average of all
collected average port data
is calculated.

The minimum frontend I/Os
rate on this port over an

Minimum Port IO – Frontend

entire collection interval. For
example, if collection
interval is set to five minutes,
the minimum port IO value
is collected and verified
against the previous value
every one minute, and the
lowest port I/O value
collected in the last five
minutes is considered.

The total IO is obtained by
summing up all the IO of all

The total IO of all the LDEVs
created in a specified RAID

Total IO – Frontend

the LDEVS for the given host
group.

group for the given Host
group over the entire data
collection interval.

NOTE:

If the same host

group is exposed to more
than one PORT then the IOs
to hostgroups is seen on all
PORTS where it is exposed.
Calculation of Total IO
depends on the LDEVS and
not on PORTS, while
summing up, the same
hostgroup is exposed to
more than one PORT, we
are considering only once.