Menu structure with the ControlBox
P0 - -
_ _ _ _
P1- -
P2- -
P4- -
P5- -
P6 - -
P7- -
P0 0 1
P0 0 2
P10 0
P10 1
P114
P20 0
P20 1
P216
P40 0
P40 1
P46 0
Operating value display
(or operational)
following mains ON
P3- -
P30 0
P30 1
P330
To change a parameter value, the ENTER key
must be pressed when the relevant parameter number is
displayed.
Changes can then be made using the VALUE keys
or
and must be confirmed with
to save them
and exit from the parameter.
As long as a changed value has not been confirmed by pressing ENTER, the value display will blink; this value
has not yet been stored in the frequency inverter.
During parameter changes, the display does not blink so that the display is more legible.
If a change is not to be saved, the "DIRECTION" key
can be pressed to exit from the parameter.
Accept changed value
Simultaneous actuation:
Value to factory setting
Accept changed value
Reduce value
Do not change value
(Direction key)
Parameter set display