BU 0750 GB-3311
Parameter
Setting value / Description / Note
Parameter
set
Available with option
P744
Configuration
Always visible
0 ... 9999
The option modules recognised by the frequency inverter are displayed in this parameter.
The display with the ParameterBox is in plain text.
The possible combinations are displayed in code in the ControlBox. The Customer Units in use
are displayed on the right. If another Encoder module is installed, this is indicated in the second
digit with a 1, the option PosiCon is indicated with a 2.
No I/O
XX00
Basic I/O
XX01
Standard I/O
XX02
Multi I/O
XX03
USS I/O
XX04
CAN I/O
XX05
Profibus I/O
XX06
Encoder
01XX
PosiCon
02XX
P745
... - 01
... - 02
... - 03
Module version
Always visible
0 ... 32767
Software version of the integrated
modules (only when own
processor is present).
Array level:
[01] Technology unit
[02] Customer Unit
[03] Special Extension Unit
P746
... - 01
... - 02
... - 03
Module status
Always visible
0000 ... FFFF hex
Status of the installed modules
(if active)
Array level:
[01] Technology unit
[02] Customer Unit
[03] Special Extension Unit
P747
Inverter voltage range
Always visible
1 / 2
Indicates the mains voltage range for which this device is specified.
1
= 200 … 240V
2
= 380 … 480V
P750
Overcurrent statistic
Always visible
0 ... 9999
Number of overcurrent messages during the operating period.
P751
Overvoltage statistic
Always visible
0 ... 9999
Number of overvoltage messages during the operating period.