App index – Yokogawa Standalone MW100 User Manual
Page 83
2-33
IM MW100-17E
Response
1
2
3
App
App
Index
Message Output Format (Response)
Response
Exception Code Message Output
Normal response None
""
Error response
1
"_-_Illegal_function"
2
"_-_Illegal_data_address"
3
"_-_Illegal_data_value"
4
"_-_Illegal_response_length"
5
"_-_Acknowledge"
6
"_-_Slave_device_busy"
7
"_-_Negative_acknowledge"
8
"_-_Memory_parity_error"
10
"_-_Gateway_path_unavailable"
11
"_-_Gateway_device_failed_to_respond"
Others
"_-_???"
Example
EA
06/01/23 16:59:17 C: 1 FC 16 (Write Register) 40011 + 2
06/01/23 16:59:17 R: 1 FC 16
06/01/23 16:59:17 C: 1 FC 3 (Read Register) 40011 + 2
06/01/23 16:59:17 R: 1 FC 3 - Illegal data value
E
Output of CIP Server Log (FL0, CIP)(Firmware version R3.02 or later)
• Output using the FL command.
• The CIP server information is output.
Syntax
EACRLF
yy/mo/dd_hh:mm:ss_d:_mmm...mCRLF
ENCRLF
yy Year (00 to 99)
mo Month (01 to 12)
dd Day
(01 to 31)
hh Hour (00 to 23)
mm Minute (00 to 59)
ss Second (00 to 59)
d
Command/response (C/R)
mmm...m Message (CIP command/response)
_
Blank
Example
EA
99/05/11 12:20:30 C: Register Session
99/05/11 12:20:31 R: Success
EN
Output of PCCC Slave Log (FL0, PCCC)(Firmware version R3.02 or later)
• Output using the FL command.
• The PCCC slave information is output.
2.2 ASCII Output