beautypg.com

App index, Mh recording channel settings, Mw recording operation settings – Yokogawa Standalone MW100 User Manual

Page 34

background image

1-27

IM MW100-17E

Commands

1

2

3

App

App

Index

Example

Create the folder automatically.
MDAUTO
Set the folder name to XXX100.
MDPARTIAL,XXX,100
Set the folder name to ZZZZZZ.
MDFREE,ZZZZZZ

Set the folder name to the date/time when the recording
is started.
MDDATE

Explanation • Folder type and format

Type

Naming

convention

Format

Handling of

duplicate folder

names

AUTO

DATAnnnn

DATA: Fixed

nnnn: Sequence number

0000 to 9999,
automatic update

Available
Sequence number
updating

PARTIAL xxxxnnnn

xxxx: Any 1 to 4
alphanumeric characters
nnnn: Sequence number

0000 to 9999,
automatic update

None

FREE

xxxxxxxx

xxxxxxxx: Any 1 to 8
alphanumeric characters

None

DATE

mddhhmmn

mddhhmm: Month, day,

hour, minute

m: 1 to 9, X (October),

Y (November), Z
(December)

dd: 01 to 31
hh: 00 to 23
mm: 00 to 59
n: Sequence number

(0 to 9, A to Z)

Available
Sequence number
updating

• The sequence number is managed by setting type.
You can set the starting sequence number for

the PARTIAL setting. You cannot set the starting
sequence number of AUTO and DATE settings.

• The folder name cannot be blank (only spaces).

Enter at least one character.

• If the number of characters of the folder name is 1

to 3 for the PARTIAL setting, the sequence number
is moved forward immediately after the folder
name. If the folder name is more than 4 characters,
characters after the 4th character are ignored. If the
folder name is set to DATA, consistency with the
auto setting is not maintained.

• In the FREE setting, the data is saved to the

same folder until the folder name is changed.
The recording log and alarm summary files are
overwritten when recorded to the same name. When
the recording stop action is set to Rotate, previous
old files are deleted.

• Commands can be sent or received with p2 and p3

attached regardless of the type (p1).

• For the character strings that can be used for the

folder name, see “File and Folder Name Strings” in
section 1.3.

MH

Recording Channel Settings

Setting

MHp1,p2,p3,p4
p1 Channel range (001 to 060 and A001 to

A300)

p2 Recording OFF/ON
p3 Thinning recording OFF/ON
p4 Manual sample recording OFF/ON

Query

MH[p1]?

Example

Set recording on channel 1 OFF, thinning recording ON,
and manual sample recording ON.

MH001,OFF,ON,ON

Explanation • Specify measurement channels on 001 to 060 of p1.

• If the /M1 MATH function option is not included,

MATH channels (A001 to A300) cannot be set
(including queries). However, if the pulse input
module is installed, MATH channels (A001 to A060)
can be set (including queries).

MW

Recording Operation Settings

Setting

When p2=OFF
MWp1,p2
When p2=ON and p3=DIRECT
MWp1,p2,p3,p4,p5
When p2=ON and p3=TRIGGER
MWp1,p2,p3,p4,p5,p6,p7
p1 Measurement group number (1 to 3)
p2 Recording OFF/ON
p3 Record start timing
DIRECT Record starts on record

start

TRIGGER Record starts on trigger

activation

p4 Recording stop action
SINGLE Recording stops after

creating one file

FULLSTOP Recording stops when file is

full

ROTATE Continue recording by

deleting the old data

p5 Recording interval [measurement/

times] (1, 2, 4, 5, 10)

p6 Recording data length
10M/20M/30M (units of minutes)
1H/2H/3H/4H/6H/8H/12H (units of

hours)

1D/2D/3D/5D/7D/10D (units of days)
p7 Pretrigger length[%] (0/10/20/30/40/5

0/60/70/80/90/100)

Query

MW[p1]?

Example

Turn recording of measurement group 1 ON, set the
record start timing to DIRECT, set the recording stop
action to SINGLE, and set the recording interval to 2.

MW1,ON,DIRECT,SINGLE,2

1.4 Setting Commands (System Related)