App index, Contact, Thermocouple – Yokogawa Standalone MW100 User Manual
Page 14
1-7
IM MW100-17E
Commands
1
2
3
App
App
Index
• Contact
Input Type
Contact
String
DI
Measuring Range
Level
Contact
String
LEVEL
CONTACT
Setting Range for Lower/Upper
Limit of Span
0 or 1 (0 for less than 24 V,
1 for 24 V or more)
0 or 1 (0 for contact OFF, 1
for contact ON)
Difference Computation
–1, 0, 1
–1, 0, 1
• Thermocouple
Input Type
Thermo-
couple
String
TC
Measuring Range
Type R
Type S
Type B
Type K
Type E
Type J
Type T
Type N
Type W
Type L
Type U
KPvsAu7Fe
PLATINEL
PR40-20
NiNiMo
WRe3-25
W/WRe26
Type N (AWG14)
Type XK GOST
String
R
S
B
K
E
J
T
N
W
L
U
KPvsAu7Fe
PLATINEL
PR40-20
NiNiMo
WRe3-25
WWRe26
N14
XK
Setting Range for Lower/Upper
Limit of Span
0.0 to 1760.0 °C
0.0 to 1760.0 °C
0.0 to 1820.0 °C
–200.0 to 1370.0 °C
–200.0 to 800.0 °C
–200.0 to 1100.0 °C
–200.0 to 400.0 °C
0.0 to 1300.0 °C
0.0 to 2315.0 °C
–200.0 to 900.0 °C
–200.0 to 400.0 °C
0.0 to 300.0 K
0.0 to 1400.0 °C
0.0 to 1900.0 °C
0.0 to 1310.0 °C
0.0 to 2400.0 °C
0.0 to 2400.0 °C
0.0 to 1300.0 °C
–200.0 to 600.0 °C
Differential Computation
±1760.0 °C
±1760.0 °C
±1820.0 °C
±1570.0 °C
±1100.0 °C
±1300.0 °C
±600.0 °C
±1300.0 °C
±2315.0 °C
±1100.0 °C
±600.0 °C
±300.0 K
±1400.0 °C
±1900.0 °C
±1310.0 °C
±2400.0 °C
±2400.0 °C
±1300.0 °C
±800.0 °C
• RTD
Input Type
RTD
String
RTD
Measuring Range
Pt100
[1]
[2]
JPt100
[1]
[2]
Pt100
[1]
(high
[2]
resolution)
JPt100
[1]
(high
[2]
resolution)
Ni100 SAMA
Ni100 DIN
Ni120
Pt50
Cu10 GE
Cu10 L&N
Cu10 WEED
Cu10 BAILEY
J263B
Cu10 at 20°C
a=0.00392
Cu10 at 20°C
a=0.00393
Cu25 at 0°C
a=0.00425
String
Pt100-1
Pt100-2
JPt100-1
JPt100-2
Pt100-1H
Pt100-2H
JPt100-1H
JPt100-2H
Ni100SAMA
Ni100DIN
Ni120
Pt50
Cu10GE
Cu10LN
Cu10WEED
Cu10BAILEY
J263B
Cu10a392
Cu10a393
Cu25
Setting Range for Lower/Upper Limit
of Span
–200.0 to 600.0 °C
–200.0 to 250.0 °C
–200.0 to 550.0 °C
–200.0 to 250.0 °C
–140.00 to 150.00 °C
–140.00 to 150.00 °C
–200.0 to 250.0 °C
–60.0 to 180.0 °C
–70.0 to 200.0 °C
–200.0 to 550.0 °C
–200.0 to 300.0 °C
–200.0 to 300.0 °C
–200.0 to 300.0 °C
–200.0 to 300.0 °C
0.0 to 300.0 K
–200.0 to 300.0 °C
–200.0 to 300.0 °C
–200.0 to 300.0 °C
Differential Computation
±800.0 °C
±450.0 °C
±750.0 °C
±450.0 °C
±290.00 °C
±290.00 °C
±450.0 °C
±240.0 °C
±270.0 °C
±750.0 °C
±500.0 °C
±500.0 °C
±500.0 °C
±500.0 °C
±300.0 K
±500.0 °C
±500.0 °C
±500.0 °C
The number in brackets for the setting range is the RTD measurement current (mA). If no number is
given, 1 mA, 2 mA, or both are supported.
1.3 Parameters