2 list of commands, Setting commands (system related), App index – Yokogawa Standalone MW100 User Manual
Page 10
1-3
IM MW100-17E
Commands
1
2
3
App
App
Index
1.2 List of Commands
Setting Commands (System Related)
Command
Functions
Operation
Administrator User
Page
Name
Mode
SR
Input Range Settings
Setting
Yes
No
1-16
SF
Filter Settings
Setting
Yes
No
1-17
XB
Burnout Settings
Setting
Yes
No
1-17
XJ
Reference Junction Compensation Settings
Setting
Yes
No
1-17
PF
Pulse Input Module Chattering Filter Settings
Setting
Yes
No
1-17
SA
Alarm Settings
All modes
Yes
No
1-18
VA
Alarm Hysteresis Settings
All modes
Yes
No
1-18
XA
Settings Related to Alarm
Setting
Yes
No
1-18
BD
Delay Alarm Settings
Setting
Yes
No
1-19
XD
Relay Settings
Setting
Yes
No
1-19
SO
Expression Settings
Setting
Yes
No
1-19
SK
MATH Constant Settings
Setting
Yes
No
1-20
MG
MATH Group Settings
Setting
Yes
No
1-20
RO
Report Operation and Creation Time Settings
Setting
Yes
No
1-20
RM
Report Execution Channel Settings
Setting
Yes
No
1-20
VL
Broken-Line Input Channel Settings
Setting
Yes
No
1-21
AO
Output Range Settings
Setting
Yes
No
1-21
AP
Preset Operation Settings
Setting
Yes
No
1-22
SL
Event/Action Settings
Setting
Yes
No
1-22
SI
Timer Settings
Setting
Yes
No
1-24
SQ
Match Time Settings
Setting
Yes
No
1-24
XV
Measurement Interval Settings
Setting
Yes
No
1-25
XI
Measurement Groups and A/D Integration Time Settings
Setting
Yes
No
1-25
VM
MATH Interval Settings
Setting
Yes
No
1-25
XG
Settings of Operation upon MATH Error
Setting
Yes
No
1-25
MC
File Message Settings
Setting
Yes
No
1-26
MD
Data Save Folder Settings
Setting
Yes
No
1-26
MH
Recording Channel Settings
Setting
Yes
No
1-27
MW
Recording Operation Settings
Setting
Yes
No
1-27
ML
Recording Data Length Settings
Setting
Yes
No
1-28
MR
Recording Free Space Settings
Setting
Yes
No
1-28
MX
Thinning Recording Operation Settings
Setting
Yes
No
1-28
MU
Setting Save Operation Settings
Setting
Yes
No
1-28
XK
Key Lock Settings
All modes
Yes
No
1-28
XT
Temperature Unit Settings
Setting
Yes
No
1-29
SW
Daylight Saving Time Settings
Setting
Yes
No
1-29
SS
Daylight Saving Time Operation Settings
Setting
Yes
No
1-29
BA
Settings of Strain Input Initial Balancing
Setting
Yes
No
1-29
UN
Unit Number Settings
Setting
Yes
No
1-29
SV
Rolling Average Settings
Setting
Yes
No
1-29
Yes: Permitted to use command, No: Not permitted to use command
Note
• The instrument has two operation modes. If a command intended for use in one mode
is executed while in a different mode, an error results. Switch to the proper mode before
executing the command. Queries can be used regardless of the mode.
• Setting Mode
In this mode, measurement, computation, and recording is stopped, and settings can be
changed.
• Measurement Mode
Computation and recording can be executed during measurement.
• The administrator and user distinction shows the user level specified on the instrument’
s communication login function. For details, see the MW100 Data Acquisition Unit User’s
Manual (IM MW100-01E).
• Queries can be executed by both administrator and users.