Sk math constant settings, Mg math group settings, Ro report operation and creation time settings – Yokogawa Standalone MW100 User Manual
Page 27: Rm report execution channel settings
1-20
IM MW100-17E
• Enter setting parameters for p4, p5 excluding the
decimal place.
• If p1 is set to a MATH channel between A061
and A300, you can specify four arithmetic
operations or MATH constants in p3 in addition to
a communication input channel between C001 and
C300.
• For the characters that can be used for p7, see user
specified characters in section 1.3.
SK
MATH Constant Settings
Setting
SKp1,p2
p1 Channel range (K01 to K60)
p2 MATH constants
Query
SK[p1]?
Example
Set MATH constant K01 to 1.0000E-10.
SKK01,1.0000E-10
Explanation • You can set this command on products with the /M1
MATH function option.
• See section 1.3 for the setting range for MATH
constants.
MG
MATH Group Settings
Setting
MGp1,p2
p1 MATH group number (1 to 7)
p2 Channel structure (up to 36
characters)
(A001 to A060)
Query
MG[p1]?
Example
Set MATH group number 1 to channels A001 to A003.
MG1,A001-A003
Explanation • You can set this command on products with the
/M1 MATH function option, or when the pulse input
module is installed.
• See section 1.3 for the channel setting method.
Note that the channels that can be input are A001 to
A060.
RO
Report Operation and Creation
Time Settings
Setting
When p1=OFF
ROp1
When p1=ON
ROp1,p2,p3,p4,p5,p6,p7
p1 Report operation (OFF/ON)
p2 Reset data when recording starts
ON
Reset
OFF
Do not reset
p3 Time to create daily, weekly, and
monthly reports
hh
Hour (00 to 23)
p4 Day of week to create weekly report
SUN
Sunday
MON
Monday
TUE
Tuesday
WED
Wednesday
THU
Thursday
FRI
Friday
SAT
Saturday
p5 Date to create monthly report
dd
Date (1 to 28)
p6 Handling of abnormal input values
for maximum, minimum, integral, or
average values
ERROR
The report data is “ Error”
SKIP
Ignore the abnormal input
value and use the previous
value
p7 Handling of overflow values for
integral/average values
ERROR
The report data is “ Error”
SKIP
Ignore the overflow value
and use the previous value
LIMIT
*1
The overflow value is
replaced with the upper or
lower limit
*1 The lower/upper limit value replaced differs
depending on the channel’s setting condition.
Measurement input
channel
Measurement range
upper and lower limit
Scaled measurement
input channel
Upper and lower limit
of scaling
MATH channel
Upper/lower limit of
span
Query
RO?
Example
Set the following: Resetting upon recording start and
report operation: ON; daily, weekly, and monthly reports:
hour = 0 am; weekly reports: Monday; create monthly
reports on the 1st; abnormal input value: ERROR;
overflow values: ERROR.
ROON,ON,00,MON,01,ERROR,ERROR
Explanation • You can set this command on products with the /M3
report function option.
• The hour on which daily, weekly, and monthly reports
are created is the same for all.
RM
Report Execution Channel
Settings
Setting
When p2=OFF
RMp1,p2
When p2=ON
RMp1,p2,p3,p4,p5
p1 Box number (01 to 60)
p2 Use/do not use box (OFF/ON)
p3 Channel range (001 to 060 and A001 to
A300)
p4 Unit of time for integration
OFF The integral value of the data
from each measurement or MATH
interval
1.4 Setting Commands (System Related)