Yokogawa RotaMASS 3-Series User Manual
Page 96

9. EXPLOSION PrOTECTEd TyPE INSTrUMENTS
9-20
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
9.3.2 Installation
remote type rCCF31 /EF4 with rCCS3 /ES1
Installation for RotaMaSS with /EF3 see in chapter 9.2.2.
Integral type rCCT3 /EF4
[Integral type]
Terminator
Rotamass
(Flowmeter)
FFout+
FFout–
+
–
+
–
Field Instrument
Field Instrument
Safe Area
Hazardous Area
Terminator
Saftey Barrier
L/+
N/–
Safe Area
Power supply
AC or DC
F09105.EPS
[Remote type]
Terminator
RCCF31
(Converter)
FFout+
FFout–
+
–
+
–
Field Instrument
Field Instrument
Safe Area
Hazardous Area
Terminator
Saftey Barrier
RCCS3
(Detector)
D+
D-
S1+
S1-
S2+
S2-
TP1
TP2
TP3
COM
L/+
N/–
Power supply
AC or DC
D+
D-
S1+
S1-
S2+
S2-
TP1
TP2
TP3
COM
Remote Cable
RCCY03
Outer shield
Connected shields
of cable pairs
to COM-terminal
F09106.EPS
- EJA130A (47 pages)
- EJA120A (40 pages)
- EJA438 (5 pages)
- EJA120A (6 pages)
- EJA115 (85 pages)
- EJA120A (47 pages)
- EJA120A (79 pages)
- EJA130A (2 pages)
- EJA130A (4 pages)
- EJA120A (31 pages)
- EJA210A (70 pages)
- EJA130A (4 pages)
- EJA430A (78 pages)
- EJX115A (55 pages)
- EJA210E (41 pages)
- EJA210E (96 pages)
- EJA210E (52 pages)
- EJA210E (89 pages)
- EJA210E (170 pages)
- EJX120A (4 pages)
- EJA210E (9 pages)
- EJX910A (175 pages)
- EJX910A (83 pages)
- EJX910A (9 pages)
- EJX910A (103 pages)
- FlowNavigator Software (163 pages)
- EJX910A (55 pages)
- EJA530A (67 pages)
- EJA120A (83 pages)
- EJX530A (52 pages)
- EJA110E (4 pages)
- EJA110E (85 pages)
- EJX120A (85 pages)
- EJA118 (76 pages)
- EJX118A (64 pages)
- EJA438 (72 pages)
- EJA430E (85 pages)
- EJX430A (6 pages)
- EJX430A (40 pages)
- EJX430A (76 pages)
- EJA430E (7 pages)
- EJA430E (41 pages)
- EJA430E (96 pages)
- EJX438A (10 pages)
- ADMAG AXR (194 pages)