Integral type rcct3, option- code (continued) – Yokogawa RotaMASS 3-Series User Manual
Page 70

8. GENErAL SPECIFICATIONS
8-16
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
Integral type rCCT3, Option- Code (continued) :
Options
Option
code
description
restrictions
High Driving Power
/HP
High Driving Power
not for RCCt34, recommended for RCCt36
to 39, strongly recommended for RCCt39/IR,
mandatory for RCCt39/XR
tag number
/BG
With customer specified tag number on name plate
max. 16 digits
Flange Facing
/Dn
/RJ
Flange with safety grooves acc. to En 1092-1 form D
Ring type Joint Flanges
only for D2 to D6; not HC
only for a3, a4, a5; not HC
Gas Measurement
/Ga
Gas measurement, special factory adjustments and settings
to be conform with anSI/ISa-12.27.01 select /RD
Special Calibration
/K2
2)
/K4
/K5
2)
/K6
Custom 5 pts mass-/volume-flow calibration using water with factory certificate
(traceable to German national standards)
Density adjustment + thermal treatment; (accuracy: 0.001 g/cm³)
Custom 10 pts mass-/volume-flow calibration using water with DKD certificate
(according En-17025:2005)
Density calibration with 3 different fluids incl. individual temperature compensation
with certificate (accuracy: 0.0005 g/cm³)
only RCCt34 to 39; not with /Ga
only RCCt34 to 39; not with /Ga ; not with
sanitary options
Certificates
/P2
/P3
/P6
/P8
/H1
Certificate of compliance with the order acc. to En 1024:2004 -2.1
as /P2 + test report acc. to En 1024: 2004 -2.2 (QIC)
Material certificate acc. to En 1024: 2004 -3.1
Pressure test report measuring system
oil and fat free for wetted surface acc. to aStM G93-03 level C
Sanitary type
/SF1
/SF2
/Sa
/SE
Surface roughness Ra = 0.8 µm
as /SF1 + test report roughness of wetted parts
as /SF2 + 3a- declaration of conformity and 3a- mark
as /SF2 + EHEDG certificate
not RCCt39/XR; only process connections S2,
S4, S8;
see also restrictions in table 11
not with process connection S2
not with process connection S2
Customer Presetting
/PS
Presetting sheet with customer data
has to be issued with the order; not with /Bt3
Housing Pressure test
/J1
Rupture pressure proof test and certificate:
60 bar (RCCt34, RCCt36), 40 bar (RCCt38), 10 bar (RCCt39, RCCt39/IR)
not for RCCt39/XR
X-Ray Examination
/Rt
X-ray examination of flange welding
only material SL
PMI Examination
/PM6
PaMI test (6 test points: process connection inlet + outlet, measuring tubes, flow
divider inlet + outlet)
3)
Dye Penetration test
/Pt
Dye penetration test of flange welding
Epoxy Coating
/X1
Epoxy coating of converter housing
Concentration Measurement
4)
/CSt
/Cxx
Standard concentration measurement
advanced concentration measurement, details see table „advanced Concentration
Measurement options“
Instruction Manuals
/IEn
/IDn
/IFn
Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French
n = 1 to 3 selectable
5)
n = 1 to 3 selectable
5)
n = 1 to 3 selectable
5)
Special order
/Z
Special design must be specification an extra sheet
2)
Calibration order sheet must be delivered with the order. this is available on the Flow Center Page at Coriolis/RCCx3/technical Information.
3)
Measuring tube PaMI test is performed per delivery batch.
4)
For detailed information please see tI 01R04B04-04E-E. Concentration measurement is recommended with option /K6.
5)
If no instruction manual is selected, only a CD with instruction manuals is shipped with the instrument. More than 3 manuals of one language on request.