Yokogawa RotaMASS 3-Series User Manual
Page 106

APPENdIX 1. LIST OF PArAMETErS FOr EACH BLOCK OF rOTAMASS
a-6
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
TA0102-3.EPS
AUTO
Rel.
Index
Index
Parameter Name
Factory
Default
Write
Mode
Explanation
AUTO
AUTO
O/S
Value =
MAN
AUTO
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TAG :
AI5 or AI6
0x0000
0
—
—
0
—
Disabled
0x00
AUTO
Block Header
ST_REV
0
SIMULATE
TAG_DESC
STRATEGY
ALERT_KEY
MODE_BLK
BLOCK_ERR
PV
OUT
XD_SCALE
OUT_SCALE
GRANT_DENY
IO_OPTS
STATUS_OPTS
Specified at
the time of
order
1
AUTO
(spaces)
1
16
CHANNEL
L_TYPE
Direct (1)
5 (AI5)
6 (AI6)
0
AUTO
O/S
AI5 AI6
Information on this block such as Block Tag, DD Revision,
Execution Time etc.
The revision level of the static data associated with the
function block. The revision value will be incremented
each time a static parameter value in the block is changed.
The user description of the intended application of the
block.
The strategy field can be used to identify grouping of
blocks. This data is not checked or processed by the
block.
The identification number of the plant unit. This
information may be used in the host for sorting alarms,
etc.
The actual, target, permitted, and normal modes of the
block.
This parameter reflects the error status associated with
the hardware or software components associated with a
block. It is a bit string, so that multiple errors may be
shown.
Either the primary analog value for use in executing the
function, or a process value associated with it.
May also be calculated from the READBACK value of an
AO block.
Allows the transducer analog input or output to the block to
be manually supplied when simulate is enabled. When
simulation is disabled, the simulate value and status track
the actual value and status.
1=Disabled, 2=Active
The high and low scale values, engineering units code,
and number of digits to the right of the decimal point to be
used in displaying the OUT parameter and parameters
which have the same scaling as OUT. Refer to 5.6.4 AI
Function Block Parameters for the unit available.
The primary analog value calculated as a result of
executing the function.
Options for controlling access of host computers and local
control panels to operating, tuning and alarm parameters
of the block.
Options which the user may select to alter input and
output block processing. bit 6: Low cutoff
Options which the user may select in the block processing
of status. bit 3: Propagate Failure Forward, bit 8: Uncertain
if Man mode.
The high and low scale values, engineering units code,
and number of digits to the right of the decimal point used
with the value obtained from the transducer for a specified
channel. Refer to 5.6.4 AI Function Block Parameters for
the unit available.
0 to 65535 (The number lies except decimal point)
0
O/S
O/S
O/S
The number of the logical hardware channel that is
connected to this I/O block. This information defines the
transducer to be used going to or from the physical world.
MAN
Block Tag
= O/S
Specified at
the time of
order
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4400
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4500
Determines if the values passed by the transducer block
to the AI block may be used directliy (Direct (1)) or if the
value is in different units and must be converted lineary
(Indirect (2), or with square root (Ind Sqr Root (3)) using the
input range defined by the transducer and the associated
output range. "Indirect Square Root" is not used for
Rotamass.
Parameter for option /Cxx concentration measurement (aI5) and netflow (aI6) :