2 fm – Yokogawa RotaMASS 3-Series User Manual
Page 85

9. EXPLOSION PrOTECTEd TyPE INSTrUMENTS
9-9
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
9.2 FM
Applicable standards:
FM3600, FM3610, FM3615, FM3810,
anSI/nEMa 250, IEC 60529,
anSI/ISa 12.00.01, anSI/ISa 12.22.01,
CSa-C22.2 no.157, CSa-C22.2 no.25,
CSa-C22.2 no.30, CSa-C22.2 no.0.5,
CSa-C22.2 no.142, CSa-C22.2 no.0.4,
CSa-C22.2 no.94
9.2.1 Technical data
remote detector rCCS30 ... 39/Xr
(option /FS1):
- Intrinsically safe
- aEx ia IIC, Class 1, Zone 0
- IS Class I, Division 1, Groups a,B,C,D t6
- DIP Class II / III, Division 1, Groups E,F,G
- IP67 / nEMa 4X
remote converter rCCF31 (option /FF3):
- Housing explosion proof
- Provides intrinsically safe detector circuits
- aEx [ia] IIC, Class I, Zone 1, t6
- Class I, Division 1, Groups a,B,C,D
- Class I, Division 1, Groups C,D with
option /HP
- Class II / III, Division 1, Groups E,F,G
- aIS Class I / II / III, Division 1, Groups
a,B,C,D, E,F,G
- aIS Class I / II / III, Division 1, Groups
C,D,E,F,G with /HP
- IP67 / nEMa 4X
- ambient temperature range : −40°C to +50°C
Integral type rCCT34 .. 39/Ir (option /FF3):
- Housing explosion proof
- aEx d [ia] IIC, Class I, Zone 1, t6
- Class I, Division 1, Groups a,B,C,D
- Class I, Division 1, Groups C,D with option /HP
- Class II / III, Division 1, Groups E,F,G
- IP67 / nEMa 4X
- ambient temperature range : −40°C to +50°C
temperature classification :
the remote converter RCCF31 has a t6 temperature
class rating for operation at ambient temperature
up to +50°C / +122°F.
Process temperature limits / Heat carrier fluid
temperature limits :
- Standard : -50°C to 150°C / -58°F to 302°F
- with option /Mt: -50°C to 220°C / -58°F to 428°F
- with option /Ht: 0°C to 350°C / -32°F to 662°F
Electrical data remote converter rCCF31,and
converter of Integral type rCCT3 :
- Driving circuit : terminals D+ / D-
uo = 14.5 V; Io = 47 ma; Po = 0.171 W
Lo = 15 mH; Co = 0.65 µF
- Driving circuit : terminals D+ / D- with option /HP
uo = 11.7 V; Io = 124 ma; Po = 0.363 W
Lo = 8 mH; Co = 10.3 µF
- Sensor circuits: terminals S1+/ S1- or S2+ / S2-
uo = 14.5 V; Io = 47 ma; Po = 0.363 W
Lo = 15 mH; Co = 0.65 µF
- temperature sensor circuit : terminals tP1,tP2, tP3
uo = 13.3 V; Io =40 ma; Po = 0.133 W
Lo = 20 mH; Co =0.91 µF
Electrical data remote detector rCCS30 ... 33:
- Driving circuit : terminals D+ and D
ui = 16 V; Ii = 53 ma; Pi = 0.212 W
Li = 4.2 mH; Ci = negligible small
- Driving circuit : terminals D+ / D- with option /HP
ui = 16 V; Ii = 153 ma; Pi = 0.612 W
Li = 4.2 mH; Ci = negligible small
- Sensor circuits: terminals S1+ / S1- or S2+ /S2-
ui = 16 V; Ii = 80 ma; Pi = 0.32 W
Li = 4.2 mH; Ci = negligible small
- temperature sensor circuit : terminals tP1,tP2, tP3
ui = 16 V; Ii =50 ma; Pi = 0.2 W
Li = negligible small; Ci = negligible small
Electrical data remote detector rCCS34 ... 39/Xr:
- Driving circuit : terminals D+ and D
ui = 16 V; Ii = 53 ma; Pi = 0.212 W
Li = 3.2 mH; Ci = negligible small
- Driving circuit : terminals D+ / D- with option /HP
ui = 16 V; Ii = 153 ma; Pi = 0.612 W
Li = 3.2 mH; Ci = negligible small
- Sensor circuits: terminals S1+ / S1- or S2+ /S2-
ui = 16 V; Ii = 80 ma; Pi = 0.32 W
Li = 2.1 mH; Ci = negligible small
- temperature sensor circuit : terminals tP1,tP2, tP3
ui = 16 V; Ii =50 ma; Pi = 0.2 W
Li = negligible small; Ci = negligible small