Yokogawa RotaMASS 3-Series User Manual
Page 73

8. GENErAL SPECIFICATIONS
8-19
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
remote field-mount converter rCCF31, Model-, Suffix- and Option- Code :
Model
Suffix Code
Option
Code
description
restrictions
RCCF31
Remote field-mount converter to be connected to RCCS3;
when ordered without detector combination option /nC must be selected
Power supply
-a
-D
90 - 264 V aC
24 V DC
Indicator direction
H2
n0
With indicator
Without indicator
Cable conduit connection
M
a
M20 x 1, female thread with cable glands
anSI ½´´ nPt, female thread, only cable gland for detector connection
mandatory with /FF3
Fieldbus Communication
/FB
/LC1
/EE
/Bt3
Digital communication (Foundation Fieldbus protocol)
Provides a PID control function block
Provides software download capability
With customer specified tag number of FF- communication + node address in
converter
max. 32 digits software tag + node address ;
not with /PS
Hazardous area approvals
1)
/KF3
/KF4
/FF3
/EF3
/EF4
/uF3
/uF4
atEX Flame proof converter + Intrinsic safe detector
atEX Flame proof converter + Intrinsic safe detector + Intrinsic safe fieldbus
FM approval for uSa+Canada, Flame proof converter + Intrinsic safe detector
IECEx Flame proof converter + Intrinsic safe detector
IECEx Flame proof converter + Intrinsic safe detector + Intrinsic safe fieldbus
InMEtRo Flame proof converter + Intrinsic safe detector
InMEtRo Flame proof converter + Intrinsic safe detector + Intrinsic safe fieldbus
with /HP for gas group IIB
with /HP for gas group IIB
only with cable conduit “a”; with /HP not for
groups a and B
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
GoSt approval
1)
/QR1
/QR2
/QR3
Russian GoSt approval
Kazakh GoSt approval
uzbekistan GoSt approval
see page 8
see page 8; not with /HP
see page 8; not with /HP
High Driving Power
/HP
High Driving Power
not for combination with RCCS30 to 34,
recommended for combination with RCCS36 to
39, strongly recommended for combination with
RCCS39/IR, mandatory for combination with
RCCS39/XR
tag number
/BG
With customer specified tag number on name plate
max. 16 digits
Gas Measurement
/Ga
Gas measurement, special factory adjustments and settings
select affiliated RCCS3 with /Ga
no Combination
/nC
no combination with detector
Customer Presetting
/PS
Presetting sheet with customer data
has to be issued with the order; not with /Bt3
Epoxy Coating
/X1
Epoxy coating of converter housing
Concentration Measurement
2)
/CSt
/Cxx
Standard concentration measurement
advanced concentration measurement, details see table „advanced Concentration
Measurement options“
Instruction Manuals
/IEn
/IDn
/IFn
Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French
n = 1 to 3 selectable
3)
n = 1 to 3 selectable
3)
n = 1 to 3 selectable
3)
Special order
/Z
Special design must be specification an extra sheet
1)
Select affiliated RCCS3 with the same approval type (e.g. /KFx with /KS1).
2)
For detailed information please see tI 01R04B04-04E-E. option /K6 of RCCS3 is recommended with concentration measurement.
3)
If no instruction manual is selected, only a CD with instruction manuals is shipped with the instrument. More than 3 manuals of one language on request.
remote cable rCCy03, Model-, Suffix- and Option- Code :
Model
Suffix Code
Option
Code
description
restrictions
RCCY031
RCCY032
RCCY033
RCCY034
Length in ´meter´
Length in ´feet´
Length in ´meter´
Length in ´feet´
max. ambient temperature 70°C; with /FFx or /FS1: 50°C
max. ambient temperature 70°C; with /FFx or /FS1: 50°C
max. ambient temperature 105°C; with /FFx or /FS1: 85°C
max. ambient temperature 105°C; with /FFx or /FS1: 85°C
Cable ends
-0
-1
no termination, with one termination kit
terminated
Cable length
Lxxx
Enter the length
max. 300m / 999ft (with /FFx or /FS1 max. 50m / 165ft);
the following lengths can be ordered (e.g. 3m = L003):
RCCY031-0: 3m, 5m, 10m, 15m, 30m, 50m, 100m, 150m, 200m, 250m, 300m
RCCY031-1: 3m, 5m, 10m, 15m, 30m, 50m
RCCY032-0: 10ft, 15ft, 30ft, 50ft, 100ft, 150ft, 300ft, 500ft, 1000ft
RCCY032-1: 10ft, 15ft, 30ft, 50ft, 100ft, 150ft
RCCY033-0: 3m, 5m, 10m, 15m, 30m, 50m, 100m, 150m, 300m
RCCY033-1: 3m, 5m, 10m, 15m, 30m, 50m
RCCY034-0: 10ft, 15ft, 30ft, 50ft, 100ft, 150ft, 300ft, 500ft, 1000ft
RCCY034-1: 10ft, 15ft, 30ft, 50ft, 100ft, 150ft
options:
Hazardous area installation
termination kits
Quick delivery
/KS1
/tKxx
/QD
Blue cable for Ex-i indication
Quantity of additional termination kits
Delivery within 24 hours from factory
xx = 01 to 99
only RCCY031-1, L003, L005, L010