A-10 – Yokogawa RotaMASS 3-Series User Manual
Page 110

APPENdIX 1. LIST OF PArAMETErS FOr EACH BLOCK OF rOTAMASS
a-10
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
relative
Index
Index
Parameter Name
Factory default
Write
Mode
Explanation
54
2054
DISP_DECIMaL_MaSS_FLoW
xxxx.XX
-
the decimal point position of the mass flow
value on the LCD display.
55
2055
DISP_DECIMaL_VoLuME_FLoW
xxxx.XX
-
the decimal point position of the volume
flow value on the LCD display.
56
2056
DISP_DECIMaL_DEnSItY
xx.XXXX
-
the decimal point position of the density
value on the LCD display.
57
2057
DISP_DECIMaL_tEMPERatuRE
xxxxx.X
-
the decimal point position of the temperature
value on the LCD display.
58
2058
DISP_DECIMaL_ConCEntR_MEaS xxxx.XX
-
the decimal point position of the concentration
measurement value on the LCD display.
59
2059
DISP_DECIMaL_nEt_FLoW
xxxx.XX
-
the decimal point position of the net flow
value on the LCD display.
60
2060
DISP_DECIMaL_It1
xxxxx.XX
-
the decimal point position of the out value
of It1 block on the LCD display.
61
2061
DISP_DECIMaL_It2
xxxxx.XX
-
the decimal point position of the out value
of It2 block on the LCD display.
62
2062
DISP_It1_unItS_InDEX
none
-
the unit index of the out value of It1 block
on the LCD display.
63
2063
DISP_It2_unItS_InDEX
none
-
the unit index of the out value of It2 block
on the LCD display.
64
2064
DISP_ContRaSt
4
-
the contrast of the LCD display.
65
2065
DISP_PERIoD
1 s
-
the update cycle of the LCD display.
66
2066
DISP_LanGuaGE
English
-
the language on the LCD display.
67
2067
FLoW_DIRECtIon
Forward
o/S
Direction of flow
68
2068
BI_DIRECtIon
Bi-direction
o/S
Selects the Bi-direction mode (bi-direction/
uni-direction).
69
2069
auto_ZERo_tIME
3 min
o/S
Defines the execution time of the autozero
function.
70
2070
auto_ZERo_EXE
not Execute
o/S
a user can execute the autozero performing
by this parameter.
after autozero execution is completed, this
value returns to “not Execute” automatically.
the execution time is defined by auto_
ZERo_tIME.
71
2071
auto_ZERo_VaLuE
Set after adjust-
ment
-
Indicates the result value of the autozero
execution.
72
2072
auto_ZERo_FLuCtuatIon
Set after adjust-
ment
-
Indicates the factory autozero range.
73
2073
aZ_InIt_MaSS_FLoW
Set after adjust-
ment
-
Indicates the last autozero value for mass
flow.
74
2074
aZ_InIt_DEnSItY
Set after adjust-
ment
-
Indicates the density at the last autozero for
mass flow.
75
2075
aZ_InIt_tEMP
Set after adjust-
ment
-
Indicates the temperature at the last
autozero for mass flow.
76
2076
MaSS_FLoW_FIX_VaL_SEL
Inhibit
o/S
this parameter enables the function of
MaSS_FLoW_FIXED_VaLuE.
When the value is “Inhibit”, the function of
MaSS_FLoW_FIXED_VaLuE does not
perform.
When the value is “Enable”, the function of
MaSS_FLoW_FIXED_VaLuE performs.
77
2077
MaSS_FLoW_FIXED_VaLuE
0.0 t/h
o/S
this parameter indicates a fix mass flow
value. the set value is added to the
autozero value.
78
2078
DEnSItY_FIX_VaL_SEL
Inhibit
o/S
this parameter enables the function of
REFEREnCE_DEnSItY.
When the value is “Inhibit” the function does
not perform. When the value is “Enabled”
the function performs.
If gas measurement (/Ga) is ordered, this
parameter is “Enabled”.