Yokogawa RotaMASS 3-Series User Manual
Page 44

5. CONFIGUrATION
5-20
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
13) dISP_SELECT_2
(relative Index 51)
Selects the data to be displayed on the
second line of the LCD indicator, as fol-
lows:
see DISP_SELECt_1
255 : none
14) dISP_SELECT_3
(relative Index 52)
Selects the data to be displayed on the
third line of the LCD indicator, as follows:
see DISP_SELECt_1
255 : none
15) dISP_SELECT_4
(relative Index 53)
Selects the data to be displayed on the
fourth line of the LCD indicator, as follows:
see DISP_SELECt_1
255 : none
16) dISP_dECIMAL_MASS_FLOW
(relative Index 54)
Selects the format of the mass flow value
to be displayed on the LCD indicator, as
follows:
1 = xxxxxxx: no decimal point (7 digits)
2 = xxxxx.X: 1 digit after DP resolution
3 = xxxx.XX: 2 digit after DP resolution
4 = xxx.XXX: 3 digit after DP resolution
5 = xx.XXXX: 4 digit after DP resolution
6 = x.XXXXX: 5 digit after DP resolution
17) dISP_dECIMAL_VOLUME_FLOW
(relative Index 55)
Selects the format of the volume flow
value to be displayed on the LCD indica-
tor, as follows:
see DISP_DECIMaL_MaSS_FLoW
18) dISP_dECIMAL_dENSITy
(relative Index 56)
Selects the format of the density value
to be displayed on the LCD indicator, as
follows:
see DISP_DECIMaL_MaSS_FLoW
19) dISP_dECIMAL_TEMPErATUrE
(relative Index 57)
Selects the format of the temperature
value to be displayed on the LCD indica-
tor, as follows:
see DISP_DECIMaL_MaSS_FLoW
20) dISP_dECIMAL_IT1
(relative Index 60)
Selects the format of the interator 1 value
to be displayed on the LCD indicator, as
follows:
1 = xxxxxxxx: no decimal point (8 digits)
2 = xxxxxx.X: 1 digit after DP resolution
3 = xxxxx.XX: 2 digit after DP resolution
4 = xxxx.XXX: 3 digit after DP resolution
5 = xxx.XXXX: 4 digit after DP resolution
6 = xx.XXXXX: 5 digit after DP resolution
7 = x.XXXXXX: 6 digit after DP resolution
21) dISP_dECIMAL_IT2
(relative Index 61)
Selects the format of the interator 2 value
to be displayed on the LCD indicator, as
follows:
see DISP_DECIMaL_It1
22) dISPLAy_CONTrAST
(relative Index 64)
Sets the display contrast of the LCD indi-
cator.
Setting range: 0 to 23
Default: 4
23) dISPLAy_PErIOd
(relative Index 65)
Sets the display refresh cycle of the LCD
indicator.
Setting range: 0.5sec; 1sec; 2sec
Default: 1sec
24) dISPLAy_LANGUAGE
(relative Index 66)
Sets the display language for the indica-
tion of error, alarms and warning on the
LCD indicator.
Setting range: English; German; French
Default: English