APPENdIX 1. LIST OF PArAMETErS FOr EACH BLOCK OF rOTAMASS

a-5

IM 01R04B05-00E-E 3rd edition July 30, 2010 -00

all Rights Reserved. Copyright © 2005, Rota Yokogawa

ta0102-2.EPS

1)

Initial value: all limits are set to plus or minus infinity (+InF or -InF), which is the same as no limit. IEEE 754-1985 defines the floating

point representation of plus and minus infinity.

auto

Rel.

Index

Index

Parameter name

Factory
Default

Write

Mode

Explanation

auto

auto

auto

auto

17

18

19

20
21

22

23

24

25
26

27

28
29

30
31

32

0.0 (aI1)
0.0 (aI2)
0.0 (aI3)
0.0 (aI4)

0

0

auto

LoW_Cut

PV_FtIME

0

HI_HI_LIM

FIELD_VaL

uPDatE_EVt

BLoCK_aLM

aLaRM_SuM

aCK_oPtIon

aLaRM_HYS

HI_HI_PRI

HI_PRI
HI_LIM

Lo_PRI

Lo_LIM

Lo_Lo_PRI

1. #InF

1)

auto

0xffff

0.5%

33

Lo_Lo_LIM

HI_HI_aLM

auto

aI1 aI2

4117

4118

4119

4120

4121

4122

4123

4124

4125
4126
4127
4128
4129
4130
4131

4132

4133

4017

4018

4019

4020
4021

4022

4023

4024

4025
4026
4027
4028
4029
4030

4031

4032

4033

Raw value of the field device in percent of thePV range,
with a status reflecting the transducer condition, before
signal characterization (L_tYPE), filtering (PV_FtIME), or
low cut (LoW_Cut).

the block alarm is used for all configuration, hardware,
connection failure or system problems in the block. the
cause of the alert is entered in the subcode field. the first
alert to become active will set the active status in the
Status attribute. as soon as the unreported status is
cleared by the alert reporting task, another block alert may
be reported without clearing the active status, if the
subcode has changed.

the current alert status, unacknowledged states,
unreported states, and disabled states of the alarms
associated with the function block.

Selection of whether alarms associated with the block will
be automatically acknowledged.
amount the PV must return within the alarm limits before
the alarm condition clears. alarm Hysteresis is expressed
as a percent of the PV span. 0 to 50

Priority of the high high alarm. 0, 1, 3 to 15

Priority of the high alarm. 0, 1, 3 to 15
the setting for high alarm in engineering units.

Priority of the low alarm. 0, 1, 3 to 15
the setting for the low alarm in engineering units.
Priority of the low low alarm. 0, 1, 3 to 15
the setting of the low low alarm in engineering units

.

the status for high high alarm and its associated time stamp

.

the status for high alarm and its associated time stamp

.

the status of the low alarm and its associated time stamp

.

the status of the low low alarm and its associated time
stamp.

this alert is generated by any change to the static data

.

Sets low cut point of output. this low cut value become
available by setting "Low cutoff" to "Io-oPtS".

time constant of a single exponential filter for the PV, in
seconds.

the setting for high high alarm in engineering units.

auto

0

auto
auto

34

HI_aLM

4134

4034

35

Lo_aLM

4135

4035

36

Lo_Lo_aLM

4136

4036

1. #InF

1)

-1. #InF

1)

0
-1. #InF

1)

auto

aI3 aI4

4217

4218

4219

4220

4221

4222

4223

4224

4225
4226
4227
4228
4229
4230
4231

4232

4233

4234
4235
4236

4317

4318

4319

4320

4321

4322

4323

4324

4325
4326
4327
4328
4329
4330
4331

4332

4333

4334
4335
4336