Remote detector rccs3, option- code – Yokogawa RotaMASS 3-Series User Manual
Page 72

8. GENErAL SPECIFICATIONS
8-18
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
remote detector rCCS3, Option- Code :
Options
Option
code
description
restrictions
Hazardous area approvals
1)
/KS1
/FS1
/ES1
/uS1
atEX intrinsically safe approval
FM approval for uSa + Canada
IECEx intrinsically safe approval
InMEtRo intrinsically safe approval for Brazil
only with cable conduit ´a´
GoSt approval
1)
/QR1
/QR2
/QR3
Russian GoSt approval
Kazakh GoSt approval
uzbekistan GoSt approval
see page 8; not with /Lt
see page 8; not for RCCS39/XR; not with /Lt
see page 8; not for RCCS39/XR; not with /Lt
Dual Seal approval
/DS
/RD
Dual Seal approval (conform with anSI/ISa-12.27.01)
Rupture disk
only RCCS34 to 39/XR; only with /FS1; not with
process connection a5
only RCCS34 to 39/IR, preferable with /Ga, not
with /tx, mandatory if /DS + /Ga is selected
tag number
/BG
With customer specified tag number on name plate
max. 16 digits
Flange Facing
/Dn
/RJ
Flange with safety grooves acc. to En 1092-1 form D
Ring type Joint Flanges
only for D2 to D6; not HC
only for a3, a4, a5; not HC
Gas Measurement
/Ga
Gas measurement, special factory adjustments and settings
select affiliated RCCF31 with /Ga;
to be conform with anSI/ISa-12.27.01 select /RD
Low temperature version
/Lt
-200°C < t
medium
< 150°C
not RCCS30 to 33; not with /KS1, /FS1, /ES1,
/uS1, /Mt, /Ht, /t1, /t2, /t3, /QR1, /QR2, /QR3
Extended temperature range
/Mt
-70°C < t
medium
< 230°C
not RCCS30 to 33; always with /S2 or /tx;
remote cable RCCY033/034 recommended
High temperature version
/Ht
t
medium
up to 350°C
only with /tx; only RCCS34 to 39/IR;
remote cable RCCY033/034 recommended
Special Calibration
/K2
2)
/K4
/K5
2)
/K6
Custom 5 pts mass-/volume-flow calibration using water with factory certificate
(traceable to German national standards)
Density adjustment + thermal treatment; (accuracy: 0.001 g/cm³
Custom 10 pts mass-/volume-flow calibration using water with DKD certificate
(according En-17025:2005)
Density calibration with 3 different fluids incl. individual temperature compensation
with certificate (accuracy: 0.0005 g/cm³)
only RCCS31 to 39; not with /Ga
only RCCS32 to 39; not with /Ga; not with
sanitary options; only available if converter is
also ordered
Certificates
/P2
/P3
/P6
/P8
/H1
Certificate of compliance with the order acc. to En 1024:2004 -2.1
as /P2 + test report acc to En 1024: 2004 -2.2 (QIC)
Material certificate acc to En 1024: 2004 -3.1
Pressure test report measuring system
oil and fat free for wetted surface acc. to aStM G93-03 level C
Sanitary type
/SF1
/SF2
/Sa
/SE
Surface roughness Ra = 0.8 µm
as /SF1 + test report roughness of wetted parts
as /SF2 + 3a- declaration of conformity and 3a- mark
as /SF2 + EHEDG- certificate
only RCCS34 to 39/IR; only process connections
S2, S4, S8; see also restrictions in table 11
not with process connection S2
not with process connection S2
Mounting set
/PD
2 inch pipe mounting set
only RCCS30 to 33; not with /tx; recommended
for RCCS30
Housing Pressure test
/J1
Rupture pressure proof test and certificate:
60 bar (RCCS34, RCCS36), 40 bar (RCCS38), 10 bar (RCCS39, RCCS39/IR)
not for RCCS30 to 33 + RCCS39/XR
Customer insulation / Heating
/S2
terminal box on extension for high or low process temperature
not with /t1 ... /t3
Factory Insulating / Heating
/t1
/t2
/t3
Insulation
Insulation + Heat carrier heating
Insulation + Heat carrier heating with ventilation
not for RCCS39/XR
not for RCCS39/XR
not for RCCS39/XR
X-Ray Examination
/Rt
X-ray examination of flange welding
not with material HC
PMI Examination
/PM4
/PM6
PaMI test (4 test points: process connection inlet + outlet, flow divider inlet +
outlet)
3)
PaMI test (6 test points: process connection inlet + outlet, measuring tubes, flow
divider inlet + outlet)
3)
only RCCS30 to 33
not RCCS30 to 33
Dye Penetration test
/Pt
Dye penetration test of flange welding
Stainless steel cable gland
/BS
Cable gland stainless steel
Special order
/Z
Special design must be specification an extra sheet
1)
Select affiliated converter RCCF31 with the same approval type (e.g. atEX).
2)
Calibration order sheet must be delivered with the order. this is available on the Flow Center Page at Coriolis/RCCx3/technical Information.
3)
Measuring tube PaMI test is performed per delivery batch.