A1.2 al function block – Yokogawa RotaMASS 3-Series User Manual
Page 104

APPENdIX 1. LIST OF PArAMETErS FOr EACH BLOCK OF rOTAMASS
a-4
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
A1.2 Al Function Block
Parameter for massflow (aI1), volumeflow (aI2), density (aI3) and temperature (aI4) :
ta0102-1.EPS
auto
Rel.
Index
Index
Parameter name
Factory
Default
Write
Mode
Explanation
auto
auto
o/S
Value =
Man
auto
4000
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
taG: aI1, aI2,
aI3 or aI4
0x0000
0
—
—
0
—
Disabled
0x00
auto
4015
Block Header
St_REV
0
SIMuLatE
taG_DESC
StRatEGY
aLERt_KEY
MoDE_BLK
BLoCK_ERR
PV
out
XD_SCaLE
out_SCaLE
GRant_DEnY
Io_oPtS
StatuS_oPtS
Specified at
the time of
order
1
auto
(spaces)
1
16
4016
CHannEL
L_tYPE
Direct (1)
1 (aI1)
2 (aI2)
3 (aI3)
4 (aI4)
0
auto
o/S
aI1 aI2
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4215
4116
Information on this block such as Block tag, DD Revision,
Execution time etc.
the revision level of the static data associated with the
function block. the revision value will be incremented
each time a static parameter value in the block is changed.
the user description of the intended application of the
block.
the strategy field can be used to identify grouping of
blocks. this data is not checked or processed by the
block.
the identification number of the plant unit. this
information may be used in the host for sorting alarms,
etc.
the actual, target, permitted, and normal modes of the
block.
this parameter reflects the error status associated with
the hardware or software components associated with a
block. It is a bit string, so that multiple errors may be
shown.
Either the primary analog value for use in executing the
function, or a process value associated with it.
May also be calculated from the REaDBaCK value of an
ao block.
allows the transducer analog input or output to the block to
be manually supplied when simulate is enabled. When
simulation is disabled, the simulate value and status track
the actual value and status.
1=Disabled, 2=active
the high and low scale values, engineering units code,
and number of digits to the right of the decimal point to be
used in displaying the out parameter and parameters
which have the same scaling as out. Refer to 5.6.4 aI
Function Block Parameters for the unit available.
the primary analog value calculated as a result of
executing the function.
options for controlling access of host computers and local
control panels to operating, tuning and alarm parameters
of the block.
options which the user may select to alter input and
output block processing. bit 6: Low cutoff
options which the user may select in the block processing
of status. bit 3: Propagate Failure Forward, bit 8: uncertain
if Man mode.
the high and low scale values, engineering units code,
and number of digits to the right of the decimal point used
with the value obtained from the transducer for a specified
channel. Refer to 5.6.4 aI Function Block Parameters for
the unit available.
0 to 65535 (the number lies except decimal point)
0
o/S
o/S
o/S
the number of the logical hardware channel that is
connected to this I/o block. this information defines the
transducer to be used going to or from the physical world.
Determines if the values passed by the transducer block
to the aI block may be used directliy (Direct (1)) or if the
value is in different units and must be converted lineary
(Indirect (2), or with square root (Ind Sqr Root (3)) using the
input range defined by the transducer and the associated
output range. "Indirect Square Root" is not used for
Rotamass.
Man
Block tag
= o/S
aI3 aI4
4200 4300
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4115
4216
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
Specified at
the time of
order