Tb120: hist_ord – Yokogawa RotaMASS 3-Series User Manual
Page 46

5. CONFIGUrATION
5-22
IM 01R04B05-00E-E 3rd edition July 30, 2010 -00
all Rights Reserved. Copyright © 2005, Rota Yokogawa
TB120: HIST_Ord
Kind
Hex
Name
description
none
0x0000
no error
Error
0x0101
E-01
Frequency Fault
0x0102
E-02
Signal Fault
0x0103
E-03
EEPRoM Fault
0x0104
E-04
CPu Fault
0x0105
E-05
DSP Fault
0x0106
E-06
Sensor 1 Signal Fault
0x0107
E-07
Sensor 2 Signal Fault
0x0108
E-08
temp Sensor Fault
alarm
0x020E
a-14
Slug Detection
0x020F
a-15
Empty Pipe Detection
0x0210
a-16
Corrosion Detection
Warning
0x0301
W-01
Density Lower 0.3 kg/l
0x0302
W-02
Fixed Dens selected (Density only)
0x0303
W-03
Fixed temp selected
0x0304
W-04
Fixed Mass flow selected (MF only)
0x0306
W-06
autozero Value out of Range
0x0307
W-07
autozero Fluctuation out of Range
TB121: HIST_ABS_Err and TB117: Err_STATUS
Kind
Hex
Name
description
Error
0x00000001
E-01
Frequency Fault
0x00000002
E-02
Signal Fault
0x00000004
E-03
EEPRoM Fault
0x00000008
E-04
CPu Fault
0x00000010
E-05
DSP Fault
0x00000020
E-06
Sensor 1 Signal Fault
0x00000040
E-07
Sensor 2 Signal Fault
0x00000080
E-08
temp Sensor Fault
TB122: HIST_ABS_ALM and TB118: ALM_STATUS
Kind
Hex
Name
description
alarm
0x00002000
a-14
Slug Detection
0x00004000
a-15
Empty Pipe Detection
0x00008000
a-16
Corrosion Detection
TB123: HIST_ABS_WArNG and TB119: WArNG_STATUS
Kind
Hex
Name
description
Warning
0x00000001
W-01
Density Lower 0.3 kg/l
0x00000002
W-02
Fixed Dens selected (Density only)
0x00000004
W-03
Fixed temp selected
0x00000008
W-04
Fixed Mass flow selected (MF only)
0x00000020
W-06
autozero Value out of Range
0x00000040
W-07
autozero Fluctuation out of Range
0x00000000
no error/
alarm/
warning
Parameter for indication of actual and history errors, alarms and warnings